High Power Laser and Particle Beams, Volume. 33, Issue 12, 123023(2021)

Evaluation of measurement uncertainty about power density for high power microwave effects test

Longquan Zhong1...2, Yu Miao3,*, Gang Zhao1,2, Jiangchuan Lin1,2, Jian Sun3, Hao Wu3, Feng Qin1,2, Zhiyang Yan1,2, Zhong Liu1,2, Yi Ge1,2 and Ying Zhang3 |Show fewer author(s)
Author Affiliations
  • 1Complicated Electromagnetic Environment Laboratory of CAEP, Mianyang 621900, China
  • 2Science and Technology on High Power Microwave Laboratory, Institute of Applied Electronics. CAEP, Mianyang 621900, China
  • 3Unit 96901 of PLA, Beijing 100094, China
  • show less
    Figures & Tables(6)
    Setup diagram of measurement system for power density
    Fish bone diagram of input quantities for power density measurement uncertainty
    Measurement evaluation layout for quantity of influence of test environment
    Measurement evaluation layout for quantity of location deviation
    • Table 1. Type B evaluation parameters of measurement uncertainty about power density for high power microwave effects test

      View table
      View in Article

      Table 1. Type B evaluation parameters of measurement uncertainty about power density for high power microwave effects test

      uncertainty quantitydistributionk-value sensitivity coefficientrelative standard uncertainty/dBrelative standard uncertainty/%
      detection power ${P_{ {\text{det} } } }$triangular$ \sqrt{6} $10.4610.58
      link attenuation $ {A'} $normal211.2027.60
      receiving gain $ {G_{\text{r}}} $rectangular$ \sqrt{3} $−10.8719.92
      location deviation $ {A_{\text{l}}} $rectangular$ \sqrt{3} $10.143.31
      frequency drift $ f $rectangular$ \sqrt{3} $20.061.41
      aiming deflection $ {A_{\text{d}}} $rectangular$ \sqrt{3} $10.143.31
      polarization mismatch ${A_{\text{P}}}$rectangular$ \sqrt{3} $10.153.54
      connection mismatch $ {A_{\text{c}}} $arc sine$ \sqrt{2} $10.214.83
      influence of test environment $ {A_{{\text{te}}}} $rectangular$ \sqrt{3} $11.2228.06
      repeatability $ {C_{\text{r}}} $normal210.132.89
    • Table 2. Recommended values of maximal step and minimal total length for field VSWR test

      View table
      View in Article

      Table 2. Recommended values of maximal step and minimal total length for field VSWR test

      frequency range/GHzΔL/cm L/cm
      <25.00±30.0
      2~42.50±15.0
      4~81.25±7.5
      >81.00±6.0
    Tools

    Get Citation

    Copy Citation Text

    Longquan Zhong, Yu Miao, Gang Zhao, Jiangchuan Lin, Jian Sun, Hao Wu, Feng Qin, Zhiyang Yan, Zhong Liu, Yi Ge, Ying Zhang. Evaluation of measurement uncertainty about power density for high power microwave effects test[J]. High Power Laser and Particle Beams, 2021, 33(12): 123023

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Jun. 7, 2021

    Accepted: --

    Published Online: Dec. 21, 2021

    The Author Email: Miao Yu (beise_cool@163.com)

    DOI:10.11884/HPLPB202133.210224

    Topics