Acta Optica Sinica, Volume. 28, Issue 7, 1279(2008)

Quantitative Phase Imaging System with Active Phase Stabilization Based on White-Light Interferometry

Li Xinhong*, Zhang Haijun, and Zhang Dongxian
Author Affiliations
  • [in Chinese]
  • show less
    References(12)

    [1] [1] Z. Chen, T. E. Milner, S. Srinivas et al.. Noninvasive imaging of in vivo blood flow velocity using optical Doppler tomography[J]. Opt. Lett., 1997, 22(14): 1119~1123

    [4] [4] D. Huang, E. A. Swanson, C. P. Lin et al.. Optical coherence tomography[J]. Science, 1991, 254: 1178~1180

    [5] [5] A. Dubois, J. Swlb, L. Vabre et al.. Phase measurements with wide-aperture interferometers[J]. Appl. Opt., 2000, 39(14): 2326~2328

    [7] [7] C. K. Hitzenberger, M. Sticker, R. Leitgeb et al.. Differential phase measurements in low-coherence interferometry without 2π ambiguity[J]. Opt. Lett., 2001, 26(23): 1864~1870

    [8] [8] P.-L. Francois, M. Monerie, C. Vassallo et al.. Three ways to implement interferential techniques: application to measurements of chromatic dispersion, birefringence, and nonlinear susceptibilities[J]. J. Lightwave Technol., 1989, 7(3): 500~513

    [9] [9] M. R. Hee, D. Huan.g, E. A. Swanson et al.. Polarization-sensitive low-coherence reflectometer for birefringence characterization and ranging[J]. J. Opt. Soc. Am. B, 1992, 9(6): 903~909

    [10] [10] J. F. de Boer, T. E. Milner, M. J. C. Van Gemert et al.. Two-dimensional birefringence imaging in biological tissue by polarization-sensitive optical coherence tomography[J]. Opt. Lett., 1997, 22(12): 934~938

    [11] [11] J. A. Izatt, M. D. Kulkarni, S. Yazdanfar et al.. In vivo bidirectional color Doppler flow imaging of picoliter blood volumes using optical coherence tomography[J]. Opt. Lett., 1997, 22(18): 1439~1445

    [12] [12] C. K. Hitzenberger, A. F. Fercher. Differential phase contrast in optical coherence tomography[J]. Opt. Lett., 1999, 24(9): 622~625

    [13] [13] A. Wax, C. Yang, R. R. Dasari et al.. Measurement of angular distributions by use of low-coherence interferometry for light-scattering spectroscopy[J]. Opt. Lett., 2001, 26(6): 322~326

    [15] [15] C. Yang, A. Wax, M. S. Hahn et al.. Phase-referenced interferometer with subwavelength and subhertz sensitivity applied to the study of cell membrane dynamics[J]. Opt. Lett., 2001, 26(16): 1271~1282

    CLP Journals

    [1] Luo Zhenyue, Xue Hui, Zhang Shuna, Shen Weidong, Gu Peifu, Zhang Yueguang. Novel Algorithm for Retrieve Thin Film Reflection Phase and Physical Thickness from White-Light Interferometry[J]. Acta Optica Sinica, 2010, 30(6): 1835

    Tools

    Get Citation

    Copy Citation Text

    Li Xinhong, Zhang Haijun, Zhang Dongxian. Quantitative Phase Imaging System with Active Phase Stabilization Based on White-Light Interferometry[J]. Acta Optica Sinica, 2008, 28(7): 1279

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Imaging Systems

    Received: Sep. 5, 2007

    Accepted: --

    Published Online: Jul. 4, 2008

    The Author Email: Xinhong Li (lixinhong@zju.edu.cn)

    DOI:

    Topics