Optics and Precision Engineering, Volume. 22, Issue 12, 3191(2014)

Optical system for full aperture backscatter diagnosis

YAN Ya-dong1,*... HE Jun-hua1, WANG Feng2 and ZHANG Min1 |Show fewer author(s)
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    References(21)

    [2] [2] ZHENG ZH J, CHEN J B, DING Y K, et al.. The laser energy injection efficiency measurement for the half-cavity target[J]. High Power Laser and Particle Beams, 2000,12(1): 43-47. (in Chinese)

    [4] [4] KIRKWOOD R K,MCCARVILLE T,FROULA D H, et al.. Calibration of initial measurements from the full aperture backscatter system on the National Ignition Facility[J]. Rev. Sci. Instrum., 2004, 75(10): 4174-4176.

    [5] [5] BOWER D E, MCCARVILLE T J,ALVAREZ S S, et al.. Full aperture backscatter station measurement system on the National Ignition Facility[J]. Rev. Sci. Instrum., 2004, 75(10): 4177-4179.

    [6] [6] MOODY J D,DATTE P,KRAUTER K, et al.. Backscatter measurements for NIF ignition targets[J]. Rev. Sci. Instrum., 2010, 81(10): 921.1-921.6.

    [9] [9] ZHAO X F, WANG CH K, KUANG L Y,et al.. The experimental method of measurement for spatial distribution of full aperture backscatter light by circular PIN-array[J].Nuclear Fusion and Plasma Physics, 2011,31(1): 43-47. (in Chinese)

    [10] [10] JIAO CH Y, WANG F, JIANG X H, et al.. Full aperture backscatter diagnosis system on Shenguang prototype laser facility[J]. Nuclear Electronics & Detection Technology, 2011,31(3): 306-311. (in Chinese)

    [11] [11] YANG ZH H. The study of near backscatter and full-aperture backscatter measurement system[D]. Chongqing: Chongqing university, 2008. (in Chinese)

    [13] [13] WEI H Y, PENG X SH, XU T, et al.. Full aperture backscatter diagnostic system on Shenguang-Ⅲprototype laser facility[J]. High Power Laser and Particle Beams, 2012,24(12): 2273-2277. (in Chinese)

    [15] [15] SONG J B, LI G P. Design and simulation of splicing of sector-shaped segments of a large optical telescope[J]. Astronomical Research & Technology, 2010,7(4): 355-361. (in Chinese)

    [16] [16] ZHANG R, HAN J J, ZANG Y ZH, et al.. Technology of segmented collimating mirror in a large solar simulator[J]. Spacecraft Environment Engineering, 2005,22(1): 50-56. (in Chinese)

    [17] [17] YANG B X. Research of SiC reflection mirror for space camera[J]. Spacecraft Recovery & Remote Sensing. 2003,24(1): 15-18.(in Chinese)

    [18] [18] WANG G L, LI SH Y, DAI Y F. Fabrication of SiC mirrors applied to space camera[J]. Materials for Mechanical Engineering, 2002,26(8): 37-38.(in Chinese)

    CLP Journals

    [1] Hou Pengcheng, Zhong Zheqiang, Wen Ping, Zhang Bin. Irradiation characteristics of laser quads on cylindrical hohlraum wall in indirect-drive facility[J]. Infrared and Laser Engineering, 2016, 45(11): 1106001

    [2] Zhou Chenghu1, Zhang Qiuhui, Huang Mingming, Huang Quanzhen. Damage effects of impurity particles on film[J]. Infrared and Laser Engineering, 2016, 45(7): 721004

    Tools

    Get Citation

    Copy Citation Text

    YAN Ya-dong, HE Jun-hua, WANG Feng, ZHANG Min. Optical system for full aperture backscatter diagnosis[J]. Optics and Precision Engineering, 2014, 22(12): 3191

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Mar. 13, 2014

    Accepted: --

    Published Online: Jan. 13, 2015

    The Author Email: Ya-dong YAN (yyd@opt.ac.cn)

    DOI:10.3788/ope.20142212.3191

    Topics