Optics and Precision Engineering, Volume. 22, Issue 12, 3191(2014)
Optical system for full aperture backscatter diagnosis
[2] [2] ZHENG ZH J, CHEN J B, DING Y K, et al.. The laser energy injection efficiency measurement for the half-cavity target[J]. High Power Laser and Particle Beams, 2000,12(1): 43-47. (in Chinese)
[4] [4] KIRKWOOD R K,MCCARVILLE T,FROULA D H, et al.. Calibration of initial measurements from the full aperture backscatter system on the National Ignition Facility[J]. Rev. Sci. Instrum., 2004, 75(10): 4174-4176.
[5] [5] BOWER D E, MCCARVILLE T J,ALVAREZ S S, et al.. Full aperture backscatter station measurement system on the National Ignition Facility[J]. Rev. Sci. Instrum., 2004, 75(10): 4177-4179.
[6] [6] MOODY J D,DATTE P,KRAUTER K, et al.. Backscatter measurements for NIF ignition targets[J]. Rev. Sci. Instrum., 2010, 81(10): 921.1-921.6.
[9] [9] ZHAO X F, WANG CH K, KUANG L Y,et al.. The experimental method of measurement for spatial distribution of full aperture backscatter light by circular PIN-array[J].Nuclear Fusion and Plasma Physics, 2011,31(1): 43-47. (in Chinese)
[10] [10] JIAO CH Y, WANG F, JIANG X H, et al.. Full aperture backscatter diagnosis system on Shenguang prototype laser facility[J]. Nuclear Electronics & Detection Technology, 2011,31(3): 306-311. (in Chinese)
[11] [11] YANG ZH H. The study of near backscatter and full-aperture backscatter measurement system[D]. Chongqing: Chongqing university, 2008. (in Chinese)
[13] [13] WEI H Y, PENG X SH, XU T, et al.. Full aperture backscatter diagnostic system on Shenguang-Ⅲprototype laser facility[J]. High Power Laser and Particle Beams, 2012,24(12): 2273-2277. (in Chinese)
[15] [15] SONG J B, LI G P. Design and simulation of splicing of sector-shaped segments of a large optical telescope[J]. Astronomical Research & Technology, 2010,7(4): 355-361. (in Chinese)
[16] [16] ZHANG R, HAN J J, ZANG Y ZH, et al.. Technology of segmented collimating mirror in a large solar simulator[J]. Spacecraft Environment Engineering, 2005,22(1): 50-56. (in Chinese)
[17] [17] YANG B X. Research of SiC reflection mirror for space camera[J]. Spacecraft Recovery & Remote Sensing. 2003,24(1): 15-18.(in Chinese)
[18] [18] WANG G L, LI SH Y, DAI Y F. Fabrication of SiC mirrors applied to space camera[J]. Materials for Mechanical Engineering, 2002,26(8): 37-38.(in Chinese)
Get Citation
Copy Citation Text
YAN Ya-dong, HE Jun-hua, WANG Feng, ZHANG Min. Optical system for full aperture backscatter diagnosis[J]. Optics and Precision Engineering, 2014, 22(12): 3191
Category:
Received: Mar. 13, 2014
Accepted: --
Published Online: Jan. 13, 2015
The Author Email: Ya-dong YAN (yyd@opt.ac.cn)