Laser & Optoelectronics Progress, Volume. 57, Issue 5, 052201(2020)

Design of Continuous Zoom Double Telecentric System and Analysis of Cam Curve

Wenwei Ye1,2、**, Jinxuan Huang1,2, Tianfu Zhou1,2, and Feng Lin1,2、*
Author Affiliations
  • 1Fujian Key Laboratory of Photonics Technology, College of Photonic and Electronic Engineering, Fujian Normal University, Fuzhou, Fujian 350007, China
  • 2Key Laboratory of Medical Optoelectronic Science and Technology, Ministry of Education, College of Photonic and Electronic Engineering, Fujian Normal University, Fuzhou, Fujian 350007, China
  • show less
    Figures & Tables(15)
    Diagram of initial system structure
    Outline drawing of the optical system
    MTF and distortion curves at -0.20×. (a) MTF curve of the system; (b) distortion curve of the system
    MTF and distortion curves at -0.33×. (a) MTF curve of the system; (b) distortion curve of the system
    MTF and distortion curves at -0.50×. (a) MTF curve of the system; (b) distortion curve of the system
    Flow chart of Zemax macro language programming method
    Cam curve obtained by Zemax macro language programming
    Grouping of zoom systems
    Cam curve obtained by dynamic optics theory
    Difference between solution data points obtained by two methods
    • Table 1. Imaging chip parameters

      View table

      Table 1. Imaging chip parameters

      Opticalsize /mmResolutionPixel size /(μm×μm)Effectivearea /(mm×mm)
      111392×10406.45×6.458.80×6.60
    • Table 2. System design parameters

      View table

      Table 2. System design parameters

      ParameterValue
      Magnification-0.5× to -0.2×
      Object field of view /mm22 to 55
      Image field of view /mm11
      Working distance /mm130
      Distortion<0.1%
      Telecentricity<0.1°
    • Table 3. Multiple structure operand settings

      View table

      Table 3. Multiple structure operand settings

      ActiveConfig 1Config 2Config 3
      APER0.0100.0150.025
      YFIE27.50016.50011.000
      THIC 1023.00014.0001.200
      THIC 1412.0003.7000.650
      TSP2 1964.72064.72064.720
    • Table 4. Partial sampling point data obtained by software method

      View table

      Table 4. Partial sampling point data obtained by software method

      ParameterValue
      Q10.1000.2000.3000.4000.500...21.70021.80021.90022.00022.100
      Q20.1120.2270.3360.4490.561...31.83432.19932.59233.02833.509
    • Table 5. Partial sampling point data obtained by dynamic optics theory

      View table

      Table 5. Partial sampling point data obtained by dynamic optics theory

      ParameterValue
      Q10.1000.2000.3000.4000.500...21.70021.80021.90022.00022.100
      Q20.1120.2250.3370.4500.563...31.93232.30432.70433.14833.648
    Tools

    Get Citation

    Copy Citation Text

    Wenwei Ye, Jinxuan Huang, Tianfu Zhou, Feng Lin. Design of Continuous Zoom Double Telecentric System and Analysis of Cam Curve[J]. Laser & Optoelectronics Progress, 2020, 57(5): 052201

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Optical Design and Fabrication

    Received: Jul. 29, 2019

    Accepted: Aug. 27, 2019

    Published Online: Mar. 5, 2020

    The Author Email: Ye Wenwei (yww_dyx@163.com), Lin Feng (lfeng127@163.com)

    DOI:10.3788/LOP57.052201

    Topics