Acta Optica Sinica, Volume. 25, Issue 12, 1718(2005)

Study on the Spectral Radiometric Calibration Method of the Spatially Modulated Imaging Fourier Transform Spectrometer

[in Chinese]1,2、*, [in Chinese]1, [in Chinese]1,2, [in Chinese]1, [in Chinese]1,2, and [in Chinese]1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    References(7)

    [1] [1] Randall B. Smith. Introduction to Hyperspectral Imaging[J]. http:∥www.microimages.com/getstart/pdf_new/hyprspec.pdf.1~24

    [2] [2] E. O′. Mongain, S. Danaher, D. Buckton et al.. Definition of the calibration requirements for an imaging spectrometer system[C]. Proc. SPIE, 1993, 1938: 88~99

    [3] [3] Edward M. Granger. A calibration method for radiometric and wavelength calibration of a spectrometers[C]. Proc. SPIE, 1998, 3648: 237~241

    [4] [4] P. Strobl, A. Mueller, D. Schlaepfer et al.. Laboratory calibration and in-fight validation of the digital air-borne imaging spectrometer DASI 7915[C]. Proc. SPIE, 1997, 3071: 225~236

    [5] [5] Gregg Vane, Thomas G. Chrien, Edward A. Miller et al.. Spectral and radiometric calibration of the airborne visible/infrared imaging spectrometer[C]. Proc. SPIE, 1987, 834: 91~105

    [6] [6] Andre Villemaire, Martin Chamberland, Jean Giroux et al.. Radiometric calibration of FT-IR remote sensing instrument[C]. Proc. SPIE, 1997, 3082: 83~91

    [10] [10] Avishai Ben-David, Agustin Ifarraguerri. Computation of a spectrum from a single-beam Fourier-transform infrared interferogram[J]. Appl. Opt., 2002, 41(6): 1181~1189

    CLP Journals

    [1] FU Zhan-fang, LIU Xue-bin. Spectrum Reconstruction Algorithms Based on Modern Spectrum Estimation[J]. Acta Photonica Sinica, 2013, 42(9): 1091

    [2] Chang Yayun, Yi Weining, Du Lili, Qiao Yanli. A New Method of on-Orbit Relative Calibration for Spatially Modulated Imaging Fourier Transform Spectrometer[J]. Laser & Optoelectronics Progress, 2015, 52(8): 83004

    Tools

    Get Citation

    Copy Citation Text

    [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese]. Study on the Spectral Radiometric Calibration Method of the Spatially Modulated Imaging Fourier Transform Spectrometer[J]. Acta Optica Sinica, 2005, 25(12): 1718

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Spectroscopy

    Received: Dec. 28, 2004

    Accepted: --

    Published Online: May. 23, 2006

    The Author Email: (cuiyanmw54124@sina.com.cn)

    DOI:

    Topics