Chinese Journal of Quantum Electronics, Volume. 41, Issue 4, 649(2024)

Background noise analysis of laser interferometer for test of TDI technology on ground

ZUO Lingyun... SHI Haosen, YAO Yuan, JIANG Yanyi and MA Longsheng |Show fewer author(s)
Author Affiliations
  • State Key Laboratory of Precision Spectroscopy, East China Normal University, Shanghai 200241, China
  • show less
    Figures & Tables(7)
    Simplified diagram of laser interferometer for gravitational wave detection in space
    Simplified diagram of experimental setup for verification of the TDI technique on ground
    Temperature difference between two AOM crystals and its effect on interferometer measurement noise.(a) AOM crystal temperature fluctuation with time; (b) Temperature difference instability fluctuation of AOM crystal with time;(b) Influence of temperature difference between two AOM crystals on measurement noise of interferometer
    Fluctuation of related parameters in an interferometer based on simulated data. (a) Temperature fluctuation of baseplate over time; (b) Fluctuation of laser power over time; (c) Fluctuation of air pressure over time; (d) Fluctuation of laser frequency over time
    Processing result of TDI data of simulation noise
    • Table 1. Temperature instability of baseplate, AOM crystal, air pressure stability, laser frequency and power stability ( length difference between interferometer arms is 5 mm )

      View table
      View in Article

      Table 1. Temperature instability of baseplate, AOM crystal, air pressure stability, laser frequency and power stability ( length difference between interferometer arms is 5 mm )

      Averaging time /sdTbaseplate /KdΔTAOM-i /Kdpair/pairdνlaser/νlaserdPpower/Ppower
      12 × 10-43 × 10-51 × 10-23 × 10-102 × 10-4
      108 × 10-51 × 10-54 × 10-31 × 10-109 × 10-5
      1025 × 10-55 × 10-62 × 10-36 × 10-115 × 10-5
      1038 × 10-51 × 10-55 × 10-31 × 10-102 × 10-4
      1048 × 10-48 × 10-54 × 10-22 × 10-92 × 10-3
    • Table 2. Magnitude of the noise contribution ( length difference between interferometer arms is 5 mm )

      View table
      View in Article

      Table 2. Magnitude of the noise contribution ( length difference between interferometer arms is 5 mm )

      Fourier frequency /mHz

      Δvbaseplate-in /

      (Hz/Hz)

      ΔvAOM-in /

      (Hz/Hz)

      Δvairp-in /

      (Hz/Hz)

      Δv0-i /

      (Hz/Hz)

      ΔvAM-PM-i /

      (Hz/Hz)

      Sum of

      the noise /

      (Hz/Hz)

      0.13 × 10-85 × 10-81 × 10-81 × 10-81 × 10-88 × 10-8
      12 × 10-72 × 10-77 × 10-88 × 10-85 × 10-83 × 10-7
      102 × 10-62 × 10-68 × 10-77 × 10-76 × 10-73 × 10-6
      1002 × 10-52 × 10-56 × 10-66 × 10-64 × 10-63 × 10-5
    Tools

    Get Citation

    Copy Citation Text

    Lingyun ZUO, Haosen SHI, Yuan YAO, Yanyi JIANG, Longsheng MA. Background noise analysis of laser interferometer for test of TDI technology on ground[J]. Chinese Journal of Quantum Electronics, 2024, 41(4): 649

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: May. 20, 2022

    Accepted: --

    Published Online: Jan. 8, 2025

    The Author Email:

    DOI:10.3969/j.issn.1007-5461.2024.04.009

    Topics