Optics and Precision Engineering, Volume. 23, Issue 8, 2164(2015)

Imaging area and contrast of THz focal plan array CW transmission imaging system

TIAN Li*... JIN Wei-qi, CAI Yi, LIU Jing and WANG Xia |Show fewer author(s)
Author Affiliations
  • [in Chinese]
  • show less
    References(12)

    [1] [1] NEC Corporation. High Sensitivity Real-Time Uncooled THz Imager and Transmission THz Microscope [Z]. 2012.

    [2] [2] INO IRXCAM-THz-384 CAMERA MODULE [Z]. 2013.

    [5] [5] GUO L T, MU K J, DENG CH, et al.. Terahertz spectroscopy and imaging[J]. Infrared and Laser Engineering,2013,42(1): 51-56.(in Chinese)

    [6] [6] BAI T ZH,JIN W Q. Photoelectric Imaging Principle and Technology [M]. Beijing: Beijing Institute of Technology Press,2010: 240-243.(in Chinese)

    [7] [7] LIU H B,ZHONG H,NICHOLAS K,et al.. Terahertz spectroscopy and imaging for defense and security applications [J]. Proceedings of the IEEE, 2007, 95(8): 1514-1527.

    [8] [8] Tydex. THz Materials[EB/OL]. http: //www.tydexoptics.com/products/thz_optics/thz_materials/. [2015-8-6]

    [9] [9] RIKEN, National Institute of Information and Computations Technology. THz DataBase[EB/OL]. http: //thzdb.org/index.php s=0.[2015-8-6]

    [10] [10] LEAHY-HOPPA M R,FITH M J, ZHENG X,et al.. Osiander Wideband terahertz spectroscopy of explosive [J].Chemical Physics Letters, 2007,434: 227-230.

    [11] [11] LEE A W M, WILLIAMS B S, KUMAR S,et al.. Real-time imaging using a 4.3-THz quantum cascade laser and a 320×240 microbolometer focal-plane array[J]. IEEE Photonics Technology Letters, 2006, 18(13): 1415-1417.

    [12] [12] LEE A W M,HU Q. Real-time, continuous-wave terahertz imaging by use of a microbolometer focal-plane array [J]. Optics Letters, 2005, 30(19): 2563-2565.

    CLP Journals

    [1] Zhang Wentao, Li Yuewen, Zhan Pingping, Xiong Xianming. Recognition of transgenic soybean oil based on terahertz time-domain spectroscopy and PCA-SVM[J]. Infrared and Laser Engineering, 2017, 46(11): 1125004

    Tools

    Get Citation

    Copy Citation Text

    TIAN Li, JIN Wei-qi, CAI Yi, LIU Jing, WANG Xia. Imaging area and contrast of THz focal plan array CW transmission imaging system[J]. Optics and Precision Engineering, 2015, 23(8): 2164

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Feb. 4, 2015

    Accepted: --

    Published Online: Oct. 22, 2015

    The Author Email: Li TIAN (tianli3628612@126.com)

    DOI:10.3788/ope.20152308.2164

    Topics