Optics and Precision Engineering, Volume. 32, Issue 11, 1701(2024)
Continuous monitoring chip of blood pH and PCO2 based on electrochemical sensing
[1] S ELOOT, F VANOMMESLAEGHE, I JOSIPOVIC et al. Association between anticoagulation strategy and quality of life in chronic hemodialysis patients. Scientific Reports, 13, 15105(2023).
[2] L H WANG, F WEI, H Y CHEN et al. A modified
[3] J ISHIDA, A KATO. Recent advances in the nutritional screening, assessment, and treatment of Japanese patients on hemodialysis. Journal of Clinical Medicine, 12, 2113(2023).
[4] J K LEYPOLDT, M PIETRIBIASI, J ECHEVERRI et al. Modeling acid-base balance during continuous kidney replacement therapy. Journal of Clinical Monitoring and Computing, 36, 179-189(2022).
[5] [5] 林晶晶, 陈少华, 姚曦, 等. 维持性血液透析患者早期死亡率及相关危险因素分析[J]. 中华肾脏病杂志, 2020, 36(8): 595-600. doi: 10.3760/cma.j.cn441217-20200312-00108LINJ J, CHENSH H, YAOX, et al. Analysis of early mortality and related risk factors in maintenance hemodialysis patients[J]. Chinese Journal of Nephrology, 2020, 36(8): 595-600.(in Chinese). doi: 10.3760/cma.j.cn441217-20200312-00108
[6] J L SEIFTER, H Y CHANG. Disorders of acid-base balance: new perspectives. Kidney Diseases, 2, 170-186(2017).
[7] U GUTH, W VONAU, J ZOSEL. Recent developments in electrochemical sensor application and technology-a review. Measurement Science and Technology, 20(2009).
[8] C BIEG, K FUCHSBERGER, M STELZLE. Introduction to polymer-based solid-contact ion-selective electrodes-basic concepts, practical considerations, and current research topics. Analytical and Bioanalytical Chemistry, 409, 45-61(2017).
[9] M A GONÇALVES, F B GONZAGA, I C S FRAGA et al. Evaluation study of different glass electrodes by an interlaboratory comparison for determining the pH of fuel ethanol. Sensors and Actuators B: Chemical, 158, 327-332(2011).
[10] J SCHWARZ, H KADEN, G PAUSCH. Development of miniaturized potentiometric nitrate- and ammonium selective electrodes for applications in water monitoring. Fresenius' Journal of Analytical Chemistry, 367, 396-398(2000).
[11] A UMEDA, M ISHIZAKA, A IKEDA et al. Recent insights into the measurement of carbon dioxide concentrations for clinical practice in respiratory medicine. Sensors, 21, 5636(2021).
[12] J B HU, A STEIN, P BÜHLMANN. A disposable planar paper-based potentiometric ion-sensing platform. Angewandte Chemie International Edition, 55, 7544-7547(2016).
[13] M PARRILLA, M CUARTERO, G A CRESPO. Wearable potentiometric ion sensors. TrAC Trends in Analytical Chemistry, 110, 303-320(2019).
[14] N Y TIUFTIAKOV, K J ROBINSON, E BAKKER. Solvatochromic coextraction-based optical carbonate nanosensors. Electroanalysis, 35(2023).
[15] R W CATTRALL, H FREISER. Coated wire ion-selective electrodes. Analytical Chemistry, 43, 1905-1906(1971).
[16] P SJÖBERG, J BOBACKA, A LEWENSTAM et al. All-solid-state chloride-selective electrode based on poly(3-octylthiophene) and tridodecylmethylammonium chloride. Electroanalysis, 11, 821-824(1999).
[17] M K A EL-RAHMAN, M R REZK, A M MAHMOUD et al. Design of a stable solid-contact ion-selective electrode based on polyaniline nanoparticles as ion-to-electron transducer for application in process analytical technology as a real-time analyzer. Sensors and Actuators B: Chemical, 208, 14-21(2015).
[18] W W JIANG, C C LIU, Y Y ZHAO et al. A solid-contact Pb2+-selective electrode based on a hydrophobic polyaniline microfiber film as the ion-to-electron transducer. Synthetic Metals, 248, 94-101(2019).
[19] S ROY, M DAVID-PUR, Y HANEIN. Carbon nanotube-based ion selective sensors for wearable applications. ACS Applied Materials & Interfaces, 9, 35169-35177(2017).
[20] A GREKOVICH, N MARKUZINA, K MIKHELSON et al. Conventional and solid-contact lithium-selective electrodes based on tris (N, N-dicyclohexylamide) neutral ionophore. Electroanalysis, 14, 551-555(2002).
[21] J BOBACKA. Potential stability of all-solid-state ion-selective electrodes using conducting polymers as ion-to-electron transducers. Analytical Chemistry, 71, 4932-4937(1999).
[22] M DONOVAL, M MICJAN, M NOVOTA et al. Relation between secondary doping and phase separation in PEDOT: PSS films. Applied Surface Science, 395, 86-91(2017).
[23] G D SULKA, K HNIDA, A BRZÓZKA. pH sensors based on polypyrrole nanowire arrays. Electrochimica Acta, 104, 536-541(2013).
[24] J X ZHANG, Y X GUO, S J LI et al. A solid-contact pH-selective electrode based on tridodecylamine as hydrogen neutral ionophore. Measurement Science and Technology, 27, 105101(2016).
[25] T MING, T T LAN, M X YU et al. Platinum black/gold nanoparticles/polyaniline modified electrochemical microneedle sensors for continuous
[26] S CHOUDHURY, D DEEPAK, G BHATTACHARYA et al. MoS2-polyaniline based flexible electrochemical biosensor: toward pH monitoring in human sweat. Macromolecular Materials and Engineering, 308, 2300007(2023).
[27] [27] 王鑫, 孙立宁, 施云波. 微型多参数水质传感器芯片的设计及应用[J]. 光学 精密工程, 2020, 28(10): 2215-2226. doi: 10.37188/OPE.20202810.2215WANGX, SUNL N, SHIY B. Design and application of miniature multi-parameter water quality sensor chip[J]. Opt. Precision Eng., 2020, 28(10): 2215-2226.(in Chinese). doi: 10.37188/OPE.20202810.2215
[28] C DUAN, G CHEN, Z L WANG et al. An ultra-sensitive electrochemical sensing platform based on nanoflower-like Au/ZnO array on carbon cloth for the rapid detection of the nitrite residues in food samples. Food Chemistry, 437, 137892(2024).
[29] M P YANG, N SUN, X C LAI et al. Screen-printed wearable sweat sensor for cost-effective assessment of human hydration status through potassium and sodium ion detection. Micromachines, 14, 1497(2023).
[30] C Q ZHANG, Y HE, J B WU et al. Fabrication of an all-solid-state carbonate ion-selective electrode with carbon film as transducer and its preliminary application in deep-sea hydrothermal field exploration. Chemosensors, 9, 236(2021).
[31] L J CHEN, F CHEN, G LIU et al. Superhydrophobic functionalized Ti(3)C(2)T(x) MXene-based skin-attachable and wearable electrochemical pH sensor for real-time sweat detection. Analytical Chemistry, 94, 7319-7328(2022).
[32] J Q YI, X P CHEN, Q H WENG et al. A simple electrochemical pH sensor based on black phosphorus nanosheets. Electrochemistry Communications, 118, 106796(2020).
[33] [33] 赵乐, 朱梦慧, 罗雪可, 等. 基于聚邻苯二胺@单壁碳纳米管修饰电极用于全血pH测定[J]. 分析试验室, 2022, 41(4): 440-443.ZHAOL, ZHUM H, LUOX K, et al. Measurement of whole blood pH based on poly-o-phenylenediamine@ single-walled carbon nanotubes modified on the glassy carbon electrode[J]. Chinese Journal of Analysis Laboratory, 2022, 41(4): 440-443.(in Chinese)
[34] G LI, X F LYU, Z WANG et al. All-solid-state carbonate-selective electrode based on screen-printed carbon paste electrode. Measurement Science and Technology, 28(2017).
[35] Z HETZLER, Y WANG, D KRAFFT et al. Flexible sensor patch for continuous carbon dioxide monitoring. Frontiers in Chemistry, 10, 983523(2022).
Get Citation
Copy Citation Text
Haixia YU, Jiale LIU, Yixin FAN, Zhiguang TAN, Qing GUO. Continuous monitoring chip of blood pH and PCO2 based on electrochemical sensing[J]. Optics and Precision Engineering, 2024, 32(11): 1701
Category:
Received: Jan. 15, 2024
Accepted: --
Published Online: Aug. 8, 2024
The Author Email: GUO Qing (guoq@tju.edu.cn)