Acta Photonica Sinica, Volume. 52, Issue 3, 0352102(2023)

Research and Application Progress of Cavity-enhanced Absorption Spectroscopy(Invited)

Xing CHAO*... Zhen HU and Ning ZHU |Show fewer author(s)
Author Affiliations
  • Department of Energy and Power Engineering, Tsinghua University, Beijing 100084, China
  • show less
    Figures & Tables(12)
    Diagram of the CEAS system
    Suppression of coupling noise by off-axis measurement
    Three-mirror structure off-axis CEAS schematic[25]
    Optical feedback cavity enhancement(OF-CEAS)optical path diagram[26]
    Schematic of OFC-resonator coupling
    Effect of intracavitary dispersion on coupling of resonator and OFC
    Experimental schematic of CE-DFCS absorption spectroscopy[54]
    The application of CEAS in DCS,using the same continuous-wave laser with phase modulator to produce a double optical comb,coherence time >2 h[56]
    VIPA spectral system signals under different conditions[61]
    • Table 1. Comparison of different light sources

      View table
      View in Article

      Table 1. Comparison of different light sources

      Type of light sourceWavelengthAdvantagesDisadvantages
      Arc lampsVacuum ultraviolet~near infraredThe output is stable in bands far from atomic lines

      Low power

      Intensity fluctuation,drift

      Light source diffusion

      Halogen lampsNear ultraviolet(>350 nm)~near infraredHigh efficiency,compact,cheap,long service lifeStable wavelength output requires precise temperature and current control
      Super-continuum sources400~2 500 nmHigh power density

      Severe optical feedback

      Power,frequency fluctuation

    • Table 2. Detection limits of air pollution detection target gases in previous studies

      View table
      View in Article

      Table 2. Detection limits of air pollution detection target gases in previous studies

      Target gasDetection band/nmCavity length/mDetection limit/(×107molecular·cm-3References
      NO2315~355188670
      410~4820.941271
      620~6904.53.4×10473
      5 238~5 2470.12.5×10974
      NO3652~6721.96.272
      630~6801.10.6234
      640~6800.55.975
      HONO355~3850.4854040
      360~375150076
      CH43 000~3 45016.2×10577
      2 3300.281.1×101378
    • Table 3. Parameters and detection limits of main biomarkers

      View table
      View in Article

      Table 3. Parameters and detection limits of main biomarkers

      Target gasDetection wavelength/μmDetection limitReferences
      CH3CHO5.798×10-898
      OCCH320.2665×10-899
      NH310.03×10-9100
      10.35×10-9101
      1.542×10-8102
      CO21.63×10-6104
      4.95×10-7101
      CO1.69×10-7103
      4.65×10-7101
      C2H63.41.2×10-10105
      NO5.21×10-9106
    Tools

    Get Citation

    Copy Citation Text

    Xing CHAO, Zhen HU, Ning ZHU. Research and Application Progress of Cavity-enhanced Absorption Spectroscopy(Invited)[J]. Acta Photonica Sinica, 2023, 52(3): 0352102

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Special Issue for Frontiers and Techniques of Laser Spectroscopy

    Received: Oct. 31, 2022

    Accepted: Dec. 15, 2022

    Published Online: Jun. 21, 2023

    The Author Email: CHAO Xing (chaox6@tsinghua.edu.cn)

    DOI:10.3788/gzxb20235203.0352102

    Topics