Optics and Precision Engineering, Volume. 30, Issue 20, 2479(2022)

Adaptive vignetting correction of corneal nerve microscopy images

Tianyu LI1... Guangxu LI1,2,*, Chen ZHANG3,4,5, Fangting LI6 and Deheng LI7 |Show fewer author(s)
Author Affiliations
  • 1School of Electronic and Information Engineering, Tiangong University, Tianjin300387, China
  • 2Tianjin Optoelectronic Detection Technology and System Laboratory, Tianjin300387, China
  • 3Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin0084, China
  • 4Tianjin Branch of National Clinical Research Center for Ocular Disease, Tianjin30038, China
  • 5Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin300384, China
  • 6Department of Ophthalmology, Peking University People’s Hospital, Beijing100044, China
  • 7Redasen Medical Technology, Beijing101100, China
  • show less
    References(23)

    [1] B S SHAHEEN, M BAKIR, S JAIN. Corneal nerves in health and disease. Survey of Ophthalmology, 59, 263-285(2014).

    [2] [2] 2李钧,张泺.角膜的神经支配[J].国外医学.眼科学分册,1990(6):341-344.LIJ, ZHANGL. Innervation of cor nea [J]. Foreign medicine. Ophthalmology, 1990 (6): 341-344(in Chinese)

    [3] [3] 3张倩, 梁晓春. 糖尿病周围神经病变的无创性筛查及评估方法的研究进展[J]. 中国医学科学院学报, 2021, 43(1): 124-129.ZHANGQ, LIANGX C. Advances in noninvasive methods for screening and evaluating diabetic peripheral neuropathy[J]. Acta Academiae Medicinae Sinicae, 2021, 43(1): 124-129.(in Chinese)

    [4] [4] 4车宁宁, 丁冠晓, 陈思远, 等. 帕金森病患者的角膜神经纤维变化特点分析[J]. 中华医学杂志, 2021, 101(7): 498-503. doi: 10.3760/cma.j.cn112137-20200614-01851CHEN N, DINGG X, CHENS Y, et al. Measurement of corneal nerve fiber parameters in patients with Parkinson's disease[J]. National Medical Journal of China, 2021, 101(7): 498-503.(in Chinese). doi: 10.3760/cma.j.cn112137-20200614-01851

    [5] [5] 5薛春燕, 黄振平, 吴艳, 等. 人活体角膜神经形态特征的激光共焦显微镜观察[J]. 南京大学学报(自然科学), 2010, 46(2): 210-215.XUEC Y, HUANGZ P, WUY, et al. In vivo visualization of the morphology of human normal and diseased corneal nerves[J]. Journal of Nanjing University (Natural Sciences), 2010, 46(2): 210-215.(in Chinese)

    [6] [6] 6徐宝腾, 杨西斌, 刘家林, 等. 高速扫描激光共聚焦显微内窥镜图像校正[J]. 光学 精密工程, 2020, 28(1): 60-68. doi: 10.3788/ope.20202801.0060XUB T, YANGX B, LIUJ L, et al. Image correction for high speed scanning confocal laser endomicroscopy[J]. Opt. Precision Eng., 2020, 28(1): 60-68.(in Chinese). doi: 10.3788/ope.20202801.0060

    [7] D V PATEL, C N J MCGHEE. In vivo confocal microscopy of human corneal nerves in health, in ocular and systemic disease, and following corneal surgery: a review. The British Journal of Ophthalmology, 93, 853-860(2009).

    [8] [8] 8纵浩天, 张运海, 王发民, 等. 大视场线扫描共聚焦全息显微成像[J]. 光学 精密工程, 2021, 29(1): 1-9. doi: 10.37188/OPE.20212901.0001ZONGH T, ZHANGY H, WANGF M, et al. Large field of view line-scanning confocal holographic microscopy[J]. Opt. Precision Eng., 2021, 29(1): 1-9.(in Chinese). doi: 10.37188/OPE.20212901.0001

    [9] B GOLEBIOWSKI, H A SWARBRICK. Mapping the corneal sub-basal nerve plexus in orthokeratology lens wear using in vivo laser scanning confocal microscopy. Investigative Ophthalmology & Visual Science, 53, 1803-1809(2012).

    [10] [10] 10王春梅, 黄晓峰, 杨家骥, 等. 激光扫描共聚焦显微镜技术[M]. 西安:第四军医大学出版社,2004.WANGC M, HUANGX F, YANGJ J, et al. Laser scanning confocal microscope technology[M]. Xian: Fourth Military Medical University Press, 2004(in Chinese)

    [11] D B GOLDMAN. Vignette and exposure calibration and compensation. IEEE Transactions on Pattern Analysis and Machine Intelligence, 32, 2276-2288(2010).

    [12] F PICCININI, A BEVILACQUA. Colour vignetting correction for microscopy image mosaics used for quantitative analyses. BioMed Research International, 2018, 7082154(2018).

    [13] Y J ZHENG, M GROSSMAN, S P AWATE et al. Automatic correction of intensity nonuniformity from sparseness of gradient distribution in medical images, 852-859(2009).

    [14] O CHERNAVSKAIA, S X GUO, T MEYER et al. Correction of mosaicking artefacts in multimodal images caused by uneven illumination. Journal of Chemometrics, 31(2017).

    [15] P D'Angelo. Radiometric alignment and vignetting calibration(2007).

    [16] K SMITH, Y P LI, F PICCININI et al. CIDRE: an illumination-correction method for optical microscopy. Nature Methods, 12, 404-406(2015).

    [17] T Y PENG, K THORN, T SCHROEDER et al. A BaSiC tool for background and shading correction of optical microscopy images. Nature Communications, 8, 14836(2017).

    [18] M TAVAKOLI, P HOSSAIN, R A MALIK. Clinical applications of corneal confocal microscopy. Clin Ophthalmol, 2, 435-445(2008).

    [19] R K LENZ, R Y TSAI. Techniques for calibration of the scale factor and image center for high accuracy 3-D machine vision metrology. IEEE Transactions on Pattern Analysis and Machine Intelligence, 10, 713-720(1988).

    [20] M D GROSSBERG, S K NAYAR. Modeling the space of camera response functions. IEEE Transactions on Pattern Analysis and Machine Intelligence, 26, 1272-1282(2004).

    [21] LIKAR, MAINTZ, VIERGEVER, et al, LIKAR, MAINTZ, VIERGEVER, et al, LIKAR, MAINTZ, VIERGEVER, et al. Retrospective shading correction based on entropy minimization. Journal of Microscopy, 197, 285-295(2000).

    [23] Z WANG, A C BOVIK, H R SHEIKH et al. Image quality assessment: from error visibility to structural similarity. IEEE Transactions on Image Processing, 13, 600-612(2004).

    Tools

    Get Citation

    Copy Citation Text

    Tianyu LI, Guangxu LI, Chen ZHANG, Fangting LI, Deheng LI. Adaptive vignetting correction of corneal nerve microscopy images[J]. Optics and Precision Engineering, 2022, 30(20): 2479

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Information Sciences

    Received: May. 7, 2022

    Accepted: --

    Published Online: Oct. 27, 2022

    The Author Email: LI Guangxu (liguangxu@tiangong.edu.cn)

    DOI:10.37188/OPE.20223020.2479

    Topics