Journal of Innovative Optical Health Sciences, Volume. 14, Issue 3, 2150010(2021)

Model eye tool for retinal optical coherence tomography instrument calibration

Hongting Wang... Wenli Liu, Zhixiong Hu*, Xiuyu Li, Fei Li and Liangcheng Duan |Show fewer author(s)
Author Affiliations
  • Center for Medical Metrology, National Institute of Metrology Beijing 100029, P. R. China
  • show less
    References(16)

    [1] [1] D. Huang, E. A. Swanson, C. P. Lin, J. S. Schuman, W. G. Stinson, W. Chang, M. R. Hee, T. Flotte, K. Gregory, C. A. Puliafito, J. G. Fujimoto, "Optical coherence tomography," Science 254, 1178–1181 (1991).

    [2] [2] X. Wang, Z. Li, N. Nan, Y. Bu, A. Zeng, S. Osami, X. Wang, "A simple system of swept source optical coherence tomography for a large imaging depth range," Opt. Commun. 431, S003040181830779X- (2018).

    [3] [3] J. A. Izatt, M. R. Hee, E. A. Swanson, C. P. Lin, D. Huang, J. S. Schuman, C. A. Puliafito, J. G. Fujimoto, "Micrometer-scale resolution imaging of the anterior eye in vivo with optical coherence tomography," Arch. Ophthalmol. 112(12), 1584– 1589 (1994).

    [4] [4] G. N. Girish, T. Bibhash, R. C. Sohini, R. K. Abhishek, R. Jeny, "Segmentation of intra-retinal cysts from optical coherence tomography images using a fully convolutional neural network model," IEEE J. Biomed. Health Inform. 23(1), 296–304 (2019).

    [5] [5] X. Zou, G. Tan, Y. Shao, "Application of optical coherence tomography angiography in ocular anterior segment diseases," Chin. J. Exp. Ophthalmol. 36(5), 398–400 (2018).

    [6] [6] P. D. Woolliams, P. H. Tomlins, "Estimating the resolution of a commercial optical coherence tomography system with limited spatial sampling," Meas. Sci. Technol. 22(6), 065502 (2011).

    [7] [7] R. C. Chang, Robert, P. Johnson, C. M. Sta?ord, J. Hwang, "Fabrication and characterization of a multilayered optical tissue model with embedded scattering microspheres in polymeric materials," Biomed. Opt. Express 3(6), 1326–1339 (2012).

    [8] [8] A. Agrawal, T. J. Pfefer, N. Gilani, R. Drezek, "Three-dimensional characterization of optical coherence tomography point spread functions with a nanoparticle-embedded phantom," Opt. Lett. 35(13), 2269–2271 (2010).

    [9] [9] P. H. Tomlins, R. A. Ferguson, C. Hart, P. D. Woolliams, "Point-spread function phantoms for optical coherence tomography," National Physical Laboratory (2009).

    [10] [10] Z. Hu, B. Hao, W. Liu, B. Hong, "Research on point spread function phantom fabrication and application for evaluating resolution performance of OCT systems," Acta Opt. Sin. 35(4), 0417001 (2015).

    [11] [11] Z. Hu, W. Liu, B. Hong, B. Hao, L. Wang, J. Li, "A physical model eye with 3D resolution test targets for optical coherence tomography," Opto- Electron. Eng. 41(12), 28–38 (2014).

    [12] [12] Z. Cao, Z. Ding, Z. Hu, W. Qiao, W. Liu, X. Chen, "Model eyes with curved multilayer structure for the axial resolution evaluation of an ophthalmic optical coherence tomography device," J. Innov. Opt. Health Sci. 11(2), 1850013 (2018).

    [13] [13] J. Baxi, W. Calhoun, Y. J. Sepah, D. X. Hammer, A. Agrawal, "Retina-simulating phantom for optical coherence tomography," J. Biomed. Opt. 19(2), 21106 (2014).

    [14] [14] H. J. Lee, N. M. Samiudin, T. G. Lee, I. Doh, S. W. Lee, "Retina phantom for the evaluation of optical coherence tomography angiography based on micro- fluidic channels," Biomed. Opt. Express 10(11), 5535 (2019).

    [15] [15] ISO/TC 172/SC 7, "Ophthalmic instruments — Optical coherence tomography for the posterior segment of the human eye," Switzerland (2015).

    [16] [16] A. Fouad, T. J. Pfefer, C. Chen, W. Gong, A. Agrawal, P. H. Tomlins, P. D. Woolliams, R. A. Drezek, Y. Chen, "Variations in optical coherence tomography resolution and uniformity: A multisystem performance comparison," Biomed. Opt. Express 5(7), 2066–2081 (2014).

    Tools

    Get Citation

    Copy Citation Text

    Hongting Wang, Wenli Liu, Zhixiong Hu, Xiuyu Li, Fei Li, Liangcheng Duan. Model eye tool for retinal optical coherence tomography instrument calibration[J]. Journal of Innovative Optical Health Sciences, 2021, 14(3): 2150010

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Nov. 20, 2020

    Accepted: Feb. 8, 2021

    Published Online: Aug. 6, 2021

    The Author Email: Hu Zhixiong (huzhixiong@nim.ac.cn)

    DOI:10.1142/s1793545821500103

    Topics