Laser & Optoelectronics Progress, Volume. 57, Issue 12, 121001(2020)

Parallel Accelerated Reconstruction Method for Dual-Energy Computed Tomography Based on Graphics Processing Unit

Pingyu Zhang*
Author Affiliations
  • Security Inspection Division, First Research Institute of the Ministry of Public Security of PRC, Beijing 102200, China
  • show less
    References(23)

    [1] Fessler J A, Elbakri I A, Predrag S et al. Maximum-likelihood dual-energy tomographic image reconstruction[J]. Proceedings of SPIE, 4684, 38-49(2002).

    [2] Sukovic P, Clinthorne N H. Penalized weighted least-squares image reconstruction for dual energy X-ray transmission tomography[J]. IEEE Transactions on Medical Imaging, 19, 1075-1081(2000).

    [3] Christ G. Exact treatment of the dual-energy method in CT using polyenergetic X-ray spectra[J]. Physics in Medicine and Biology, 29, 1501-1510(1984).

    [4] Steenbeek J C M, van Kuijk C, Grashuis J L et al. Selection of fat-equivalent materials in postprocessing dual-energy quantitative CT[J]. Medical Physics, 19, 1051-1056(1992).

    [5] Goodsitt M M. Beam hardening errors in post-processing dual energy quantitative computed tomography[J]. Medical Physics, 22, 1039-1047(1995).

    [6] Alvarez R E. MacOvski A. Energy-selective reconstructions in X-ray computerised tomography[J]. Physics in Medicine and Biology, 21, 733-744(1976).

    [7] Chuang K S, Huang H K. A fast dual-energy computational method using isotransmission lines and table lookup[J]. Medical Physics, 14, 186-192(1987).

    [8] Alvarez R E, Seibert J A, Thompson S K. Comparison of dual energy detector system performance[J]. Medical Physics, 31, 556-565(2004).

    [9] Cardinal H N, Fenster A. An accurate method for direct dual-energy calibration and decomposition[J]. Medical Physics, 17, 327-341(1990).

    [10] Cardinal H N, Fenster A. Analytic approximation of the log-signal and log-variance functions of X-ray imaging systems, with application to dual-energy imaging[J]. Medical Physics, 18, 867-879(1991).

    [11] Tang S J, Mou X Q, Luo T. An iteration algorithm in dual-energy X-ray imaging based on polychromatic physics model[J]. Proceedings of SPIE, 6142, 61422R(2006).

    [12] Zou Y, Silver M D. Analysis of fast kV-switching in dual energy CT using a pre-reconstruction decomposition technique[J]. Proceedings of SPIE, 6913, 691313(2008).

    [14] Ying Z R, Naidu R, Guilbert K et al. Dual energy volumetric X-ray tomographic sensor for luggage screening. [C]∥2007 IEEE Sensors Applications Symposium, February 6-8, 2007. San Diego, CA, USA. IEEE, 1-6(2007).

    [16] Xu F, Mueller K. Accelerating popular tomographic reconstruction algorithms on commodity PC graphics hardware[J]. IEEE Transactions on Nuclear Science, 52, 654-663(2005).

    [17] Xu F, Mueller K. Real-time 3D computed tomographic reconstruction using commodity graphics hardware[J]. Physics in Medicine and Biology, 52, 3405-3419(2007).

    [19] Wei C F. Acceleration of CT image reconstruction[D]. Beijing: Institute of High Energy Physics Chinese Academy of Sciences(2008).

    [20] Bi W Y. Dual energy single slice helical CT reconstruction algorithms for luggage security inspection system[D]. Beijing: Tsinghua Univesity(2010).

    [21] Zhang H T, Yu P, Hu X Y et al. Single-slice helical CT three-dimensional image reconstruction using GPU[J]. Acta Electronica Sinica, 39, 76-81(2011).

    [22] Capital Normal University[P]. GPU acceleration method for CT image reconstruction: CN200810113846.0, 12, 15(2010).

    Tools

    Get Citation

    Copy Citation Text

    Pingyu Zhang. Parallel Accelerated Reconstruction Method for Dual-Energy Computed Tomography Based on Graphics Processing Unit[J]. Laser & Optoelectronics Progress, 2020, 57(12): 121001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Image Processing

    Received: Jul. 19, 2019

    Accepted: Oct. 29, 2019

    Published Online: Jun. 3, 2020

    The Author Email: Zhang Pingyu (zhangpy@fiscan.cn)

    DOI:10.3788/LOP57.121001

    Topics