Infrared and Laser Engineering, Volume. 50, Issue S2, 20210539(2021)

Analysis on the change of GF-7 satellite laser altimeter spot centroid position

Jiaqi Yao1...2, Guoyuan Li1,2,*, Jiyi Chen2, Xiaoqing Zhou2, Aiyan Guo3, Genghua Huang4, Xinming Tang1,2 and Bo Ai1 |Show fewer author(s)
Author Affiliations
  • 1College of Geodesy and Geomatics, Shandong University of Science and Technology, Qingdao 266590, China
  • 2Land Satellite Remote Sensing Application Center, Ministry of Natural Resources, Beijing 100048, China
  • 3Beijing Institute of Spacecraft System Engineering, Beijing 100094, China
  • 4Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai 200083, China
  • show less
    Figures & Tables(12)
    Imaging mechanism of LFC and LOASC
    Distribution of laser spot on LFI and LSI
    Flowchart of the algorithm
    Threshold constraint algorithm for extracting centroid of ellipse fitting
    Accuracy analysis of proposed algorithm
    Spot centroid coordinate statistics of LFI of laser 1 (a) and laser 2 (b)
    Changes of centroid of two beams in X and Y directions on LFI
    Centroid coordinate statistics of LSI of laser 1 (a) and laser 2 (b)
    Change of distance between spots in the LSI
    • Table 1. Accuracy evaluation of centroid extraction algorithm for footprint image(Unit: pixel)

      View table
      View in Article

      Table 1. Accuracy evaluation of centroid extraction algorithm for footprint image(Unit: pixel)

      MethodMeanRangeRMSE
      XYXYXY
      GCM2.5652.5224.9415.1852.5122.218
      TEFM0.0620.0710.0920.0880.0520.081
    • Table 2. Statistical results of monthly mean of spot centroid coordinates of LFI (Unit: pixel)

      View table
      View in Article

      Table 2. Statistical results of monthly mean of spot centroid coordinates of LFI (Unit: pixel)

      TimeLFI
      Laser 1Laser 2
      XYXY
      2020Mar.120.83263.71216.32162.51
      Apr.120.50264.51216.88162.63
      May120.35263.88216.85162.56
      Jun.120.37263.79216.87162.36
      Jul.120.52263.90216.93162.10
      Aug.120.63263.28216.81161.65
      Sep.120.51262.26216.72161.53
      Oct.120.11261.85216.35161.60
      Nov.120.33262.02216.42161.64
      Dec.120.37262.30216.31161.82
      2021Jan.120.49262.55216.00161.65
      Feb.120.36262.55216.81161.17
      Mar.120.45262.67216.62161.68
      Apr.120.43262.63216.63161.07
    • Table 3. Statistical results of monthly mean of spot centroid coordinates of LSI (Unit: pixel)

      View table
      View in Article

      Table 3. Statistical results of monthly mean of spot centroid coordinates of LSI (Unit: pixel)

      TimeLSIDistance between two spots in the LSI
      Laser 1Laser 2
      XYXY
      2020Mar.57.18313.10228.01156.670
      Apr.56.93313.35228.63156.311.05
      May56.51313.39228.84156.141.66
      Jun.56.41313.35228.79156.091.71
      Jul.56.52313.32228.81156.291.48
      Aug.56.08313.68228.77156.182.09
      Sep.55.99313.75228.68156.222.11
      Oct.55.77313.63228.82156.622.03
      Nov.56.08314.031228.71156.222.26
      Dec.55.93313.74228.67156.501.95
      2021Jan.56.22313.62228.56156.621.49
      Feb.56.50313.51228.79156.491.47
      Mar.56.47313.62228.59156.561.38
      Apr.56.48312.99228.82156.251.33
    Tools

    Get Citation

    Copy Citation Text

    Jiaqi Yao, Guoyuan Li, Jiyi Chen, Xiaoqing Zhou, Aiyan Guo, Genghua Huang, Xinming Tang, Bo Ai. Analysis on the change of GF-7 satellite laser altimeter spot centroid position[J]. Infrared and Laser Engineering, 2021, 50(S2): 20210539

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Lasers and laser optics

    Received: Aug. 5, 2021

    Accepted: --

    Published Online: Dec. 3, 2021

    The Author Email: Li Guoyuan (ligy_lasac@foxmail.com)

    DOI:10.3788/IRLA20210539

    Topics