Laser & Optoelectronics Progress, Volume. 56, Issue 9, 091701(2019)

Biological Cell Phase Imaging System Integrated with Optical Scattering Information

Ying Ji1、*, Shuang Fu2, Zhaohe Tao1, Minjie Liang1, and Yawei Wang1
Author Affiliations
  • 1 Faculty of Science, Jiangsu University, Zhenjiang, Jiangsu 212013, China
  • 2 School of Mechanical Engineering, Jiangsu University, Zhenjiang, Jiangsu 212013, China
  • show less
    Figures & Tables(11)
    Schematic of biological cell phase imaging system integrated with optical scattering information
    Flow chart of system
    Schematic of model. (a) Homogeneous cells; (b) monocytes; (c) binuclear cells
    Phase distributions. (a) Homogeneous cells; (b) monocytes; (c) binuclear cells
    Modulus square processing of phase gradient. (a) Homogeneous cells; (b) monocytes; (c) binuclear cells
    Axial distribution of modulus square of phase gradient. (a) Homogeneous cells; (b) monocytes; (c) binuclear cells
    Scattered light intensity distributions of models and diagonal distributions of scattered light intensity. (a) (d) Homogeneous cells; (b) (e) monocytes; (c) (f) binuclear cells
    Phase information of human red blood cells. (a) Phase distribution; (b) axial distribution of modulus square of phase gradient
    Analysis diagram of human neutrophils. (a) Phase distribution; (b) axial distribution of modulus square of phase gradient
    • Table 1. Horizontal coordinates of break points in axial distribution curve

      View table

      Table 1. Horizontal coordinates of break points in axial distribution curve

      Cell typeHorizontal coordinate of break point
      HomogeneousMonocyteA(53) B(204)A(53) B(100) C(157) D(204)
      BinuclearA(53) B(100) C(112) D(145)E(157) F(204)
    • Table 2. Comparison of measured values with model parameters

      View table

      Table 2. Comparison of measured values with model parameters

      Cell typeDesign parameter /μm(cell diameter/nuclear diameter)Measured value /μm(cell diameter/nuclear diameter)Average error rate /%
      Homogeneous18.0017.761.33
      Monocyte18.00/7.0017.76/6.941.08
      Binuclear18.00/7.00/4.0017.77/6.71/3.882.81
    Tools

    Get Citation

    Copy Citation Text

    Ying Ji, Shuang Fu, Zhaohe Tao, Minjie Liang, Yawei Wang. Biological Cell Phase Imaging System Integrated with Optical Scattering Information[J]. Laser & Optoelectronics Progress, 2019, 56(9): 091701