Acta Optica Sinica, Volume. 41, Issue 18, 1812003(2021)

Real-Time Phase Measuring Profilometry Based on Single-Shot Four-Grayscale Fringe Projection

Chaozhi Yang and Yiping Cao*
Author Affiliations
  • College of Electronics and Information Engineering, Sichuan University, Chengdu, Sichuan 610065, China
  • show less
    Figures & Tables(12)
    Real-time measuring system of PMP based on four-grayscale fringe pattern projection
    Projection and capturing of four-grayscale encoded fringe pattern. (a) Fringe pattern projection matrix; (b) grayscale distribution of fringe pattern projection; (c) capturing of reference fringe; (d) capturing of deformed fringe
    OPE on periodic boundary of fringe pattern. (a) Gray-scale distribution on periodic boundary of fringe pattern; (b) inaccurate segmentation of fringe pattern
    Periodic boundary searching of fringe patterns. (a) Gray value of fringe pattern; (b) gray differential of fringe pattern
    Flow chart of fringe segmention
    Binary fringe patterns with 1/3 period displacement after fringe segmentation. (a) 1st frame of binary fringe pattern; (b) 2nd frame of binary fringe pattern; (c) 3rd frame of binary fringe pattern
    Schematic of experimental setup
    Measuring experiment for knife. (a) Knife; (b) captured deformed fringe pattern; (c) binary deformed fringe pattern after segmentation; (d) extracted sinusoidal deformed fringe patterns; (e) wrapped phase; (f) 3D reconstructed result
    Real-time measuring experiment for workpiece. (a)(b)(c) Four-grayscale deformed fringe patterns captured with 0.03 s period; (d)(e)(f) corresponding wrapped phases; (g)(h)(i) corresponding reconstructed results
    Face-model reconstruction experiment. (a) Reconstruction result of FTP; (b) reconstruciton result of proposed method; (c) reconstruction result of 3-step PMP; (d) cross section of 670th column; (e) details of nose tip
    • Table 1. RMSE of reconstruction result of workpiece under each moving speed

      View table

      Table 1. RMSE of reconstruction result of workpiece under each moving speed

      Moving speed /(mm·s-1)5102030
      RMSE /mm0.0340.0370.0450.048
    • Table 2. Error analysis for face-model reconstruction results by different algorithms

      View table

      Table 2. Error analysis for face-model reconstruction results by different algorithms

      AlgorithmFTPProposed method3-step PMP
      MAE /mm0.1830.0820.067
      RMSE /mm0.2040.1280.089
    Tools

    Get Citation

    Copy Citation Text

    Chaozhi Yang, Yiping Cao. Real-Time Phase Measuring Profilometry Based on Single-Shot Four-Grayscale Fringe Projection[J]. Acta Optica Sinica, 2021, 41(18): 1812003

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Instrumentation, Measurement and Metrology

    Received: Feb. 2, 2021

    Accepted: Apr. 13, 2021

    Published Online: Sep. 3, 2021

    The Author Email: Cao Yiping (ypcao@scu.edu.cn)

    DOI:10.3788/AOS202141.1812003