Acta Optica Sinica, Volume. 33, Issue 11, 1115004(2013)

Two Parallel Planes Calibration for Two-Dimensional Object Vision Measurement

Liu Chang*
Author Affiliations
  • [in Chinese]
  • show less
    References(14)

    [1] [1] Roger Y Tsai. A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses [J]. IEEE J Robotics Automation, 1987, 3(4): 323-344.

    [2] [2] Zhang Zhengyou. A flexible new technique for camera calibration [J]. IEEE Trans Pattern Analysis and Machine Intelligence, 2000, 22(11): 1330-1334.

    [3] [3] Xue Junpeng, Su Xianyu. Camera calibration with single image based on two orthogonal one-dimensional objects [J]. Acta Optica Sinica, 2012, 32(1): 0115001.

    [4] [4] Liu Zhen, Shang Yanna. Novel calibration method for stereo vision sensor using flexible target [J]. Acta Optica Sinica, 2013, 33(3): 0315001.

    [5] [5] Yang Bowen, Zhang Liyan, Ye Nan, et al.. Camera calibration technique of wide-area vision measurement [J]. Acta Optica Sinica, 2012, 32(9): 0915001.

    [6] [6] Zhou Fuqiang, Cai Feihua. Camera calibration method based on non-metric distortion correction [J]. Chinese J Mechanical Engineering, 2009, 45(8): 228-232.

    [7] [7] Chen Tianfei, Ma Zi, Li Peng, et al.. A camera calibration method based on non-metric distortion correction [J]. Control and Decision, 2012, 21(2): 243-251.

    [8] [8] Liao Shizhong, Gao Peihuan, Su Yi, et al.. A geometric rectification method for lens camera [J]. J Image and Graphics, 2000, 5(7): 593-596.

    [9] [9] Wang Fuzhi, Huang Dagui. Accurate distortion correction study based on differential images [J]. Chinese J Scientific Instrument, 2010, 31(2): 377-382.

    [12] [12] Wei Guoqing, Ma Songde. Implicit and explicit camera calibration: theory and experiments [J]. IEEE Trans Pattern Analysis and Machine Intelligence, 1994, 16(5): 469-480.

    [13] [13] Liu Peng, Liu Weijun. Research on 3D measurement of free form surface based on computer vision technique [J]. Computer Engineering, 2005, 31(4): 58-61.

    [14] [14] J Weng, P Cohenn, M Herniod. Calibration of stereo cameras using a non-linear distortion model [C]. Atlantic: Proc 10th Int Conf on Pattern Recognition, 1990. 246-253.

    CLP Journals

    [1] Wu Ming, Li Linlin, Wei Zhenhua, Wang Hongqiao. Observation Consistency for Moving Object Tracking with Mobile Robot in Dynamic Environments[J]. Acta Optica Sinica, 2015, 35(6): 615002

    [2] Jiang Xiaodong, Yu Jiyan, Zhu Likun, Huang Jiansen. Self-Calibrated Binocular Ranging System Based on Hardware SURF Algorithm[J]. Acta Optica Sinica, 2018, 38(10): 1036001

    [3] Zhai Liang, Wang Tao, Bai Manshe, Zuo Yijuan, Su Yu, Liu Xin, Chen Jing, Zhu Liangjian. Real-Time Loss Measurement of Reflecting Mirrors Applied in Plasma Environment[J]. Acta Optica Sinica, 2017, 37(7): 712001

    [4] Lu Minxun, Ge Weiliang, Zhou Aiguo, Lü Gang, Zhou Fei. Calibrating Laser Scanning Probe with Double Virtual Circle Target[J]. Acta Optica Sinica, 2014, 34(10): 1015005

    [5] Dongsheng Yang, Shusheng Bi, Yueri Cai, Chang Yuan. Wide-Area Monocular Plane Measurement Based on Calibration on a Parallel Plane Using Multiple Targets[J]. Acta Optica Sinica, 2017, 37(10): 1015001

    Tools

    Get Citation

    Copy Citation Text

    Liu Chang. Two Parallel Planes Calibration for Two-Dimensional Object Vision Measurement[J]. Acta Optica Sinica, 2013, 33(11): 1115004

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Machine Vision

    Received: May. 3, 2013

    Accepted: --

    Published Online: Oct. 20, 2013

    The Author Email: Chang Liu (syliuch@126.com)

    DOI:10.3788/aos201333.1115004

    Topics