Acta Photonica Sinica, Volume. 39, Issue 3, 481(2010)

Dual-loop Carbon Monoxide Concentration Measurement System Based on Cavity Ring-down Technology

LI Zhi-quan*, ZHU Guo-fang, CHEN Xi, YANG Qiu-xia, LIU Shi-yuan, YAN Ju-bing, and LI Wen-chao
Author Affiliations
  • [in Chinese]
  • show less
    References(11)

    [1] [1] YANG Cheng,MENG Xiao-hong,LIU Yu-xia.Evaluation on measurement uncertainty of detector device for light interference methane measuring meter[J].Coal Science Engineering,2004,32(4):67-65.

    [2] [2] HE Gui-ying,CHEN Zhang-yue.Gas chroma to graphic determination of benzene and its homologues in atmosphere and in gas from pollution source[J]. PTCA(PARTB:CHEM ANAL),2005,41(7):479-481.

    [4] [4] ANDERSON D Z,FRISCH J C,MASSER C S.Mirror reflectrometer based on optical cavity decay time[J].Appl Opt,1984,23(8):1238-1245.

    [5] [5] O′KEEFE A,DEACON D A G.Cavity ring-down optical spectrometer for absorption measurements using pulsed laser sources[J].Rev Sci Instrurn,1988,59(12):2544-2550.

    [6] [6] STEWARD G,ATHERTON K,et al.Fiber optic intra-cavity spectroscopy:combined ring-down and ICLAS architectures using fiber lasers[C].SPIE,2001,4204:124-130.

    [7] [7] STEWARD G,WHITENETT G,CULSHAW B,et al.Design of fiber laser and sensor systems for gas spectroscopy in the near-IR[C]. SPIE,2004,5272(1):172-180.

    [8] [8] WHITENETT G,STEWARD G,ATHERTON K,et al.Optical fiber instrumentation for environmental monitoring applications[J].J Opt A:Pure Appl Opt,2004,5(4):140-145.

    [9] [9] WHITENETT G,STEWARD G,YU Hong-bo,et al.Investigation of a tuneable mode-locked fiber laser for application to multipoint gas spectroscopy[J].Journal of Lightwave Technology,2004,22(3):813-818.

    [10] [10] BROWN R S,KOZIN I.Fiber-loop ring-down spectroscopy[J].Chem Phys,2002,117(23):10444-10447.

    [11] [11] GENG Jian,ZHANG Ming-de,SUN Xiao-han.Gain locking of erbium optical fiber amplifiers[J].Chinese Journal of Electron Devices,2002,25(4):453-457.

    Tools

    Get Citation

    Copy Citation Text

    LI Zhi-quan, ZHU Guo-fang, CHEN Xi, YANG Qiu-xia, LIU Shi-yuan, YAN Ju-bing, LI Wen-chao. Dual-loop Carbon Monoxide Concentration Measurement System Based on Cavity Ring-down Technology[J]. Acta Photonica Sinica, 2010, 39(3): 481

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Jun. 18, 2009

    Accepted: --

    Published Online: May. 24, 2010

    The Author Email: Zhi-quan LI (zhuguofang5968@163.com)

    DOI:

    Topics