Acta Photonica Sinica, Volume. 52, Issue 9, 0930004(2023)

Structure Components Optimization Design of Ultraviolet Imaging Spectrometer

Jianyu YANG1,2,3、*, Xuan YANG1,2, and Jianhua ZHENG1,2
Author Affiliations
  • 1National Space Science Center,Chinese Academy of Sciences,Beijing 100190,China
  • 2Key Laboratory of Integrated Avionics and Information Technology for Complex Aerospace Systems,Beijing 100190,China
  • 3University of Chinese Academy of Sciences,Beijing 100049,China
  • show less
    Figures & Tables(26)
    Lens composition of spectrometer
    Preliminary design scheme of spectrometer structure
    Installation and fixation of reflector
    Topology optimization results of main module and collimating mirror module
    Topology optimization results of imaging objective lens frame
    Iterative convergence curve of topology optimization
    Geometric parameters of main module and collimating mirror module
    Geometric parameters of imaging objective lens frame
    Contribution of parameters to each response function
    Iterative curve of design variables
    Optimized main structure of the spectrometer
    Structure of ultraviolet imaging spectrometer
    Deformation of collimating mirror affected by gravity
    Spot diagram of optical system subjected to gravity
    Change of the surface type of collimating mirror
    Change of the surface type of grating surface type
    Spot diagram of optical system at 10 ℃
    Spot diagram of optical system at 30 ℃
    Impurity elimination diaphragm in imaging objective lens
    Stray light ray diagram
    Measuring point curve of random vibration test
    Flow chart of spectrometer setup
    • Table 1. Size parameters before and after parameter optimization

      View table
      View in Article

      Table 1. Size parameters before and after parameter optimization

      Design parameterL4L9L12L13L15L16L17L18
      Lower bound/mm8.04.0112.0109.06.05.06.05.0
      Upper bound/mm17.017.0123.0119.010.010.010.010.0
      Initial value/mm15.015.0115.0110.08.08.08.08.0
      Optimum value/mm8.74.8122.3118.66.55.36.35.1
    • Table 2. Performance comparison of spectrometer before and after structure optimization

      View table
      View in Article

      Table 2. Performance comparison of spectrometer before and after structure optimization

      ResponseRMSplus-Z/nmMass/kgf1/Hz
      Initial values17.826.95365.7
      Optimized values11.312.87205.69
    • Table 3. Random vibration test conditions

      View table
      View in Article

      Table 3. Random vibration test conditions

      Frequency range/Hz20~100100~600600~2 000
      Power spectral density+3 dB/oct0.09 g2/Hz-9 dB/oct
      Total root mean square acceleration8.6 g
      Test directionX,Y,Z triaxial
    • Table 4. Random vibration response results of spectrometer structure components

      View table
      View in Article

      Table 4. Random vibration response results of spectrometer structure components

      Random vibration directionX axisY axisZ axis
      Result of random vibration analysis(RMS)26.32 g24.99 g32.35 g
      Magnification3.12.93.8
    Tools

    Get Citation

    Copy Citation Text

    Jianyu YANG, Xuan YANG, Jianhua ZHENG. Structure Components Optimization Design of Ultraviolet Imaging Spectrometer[J]. Acta Photonica Sinica, 2023, 52(9): 0930004

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Nov. 21, 2022

    Accepted: Apr. 13, 2023

    Published Online: Oct. 24, 2023

    The Author Email: YANG Jianyu (wangpancad@126.com)

    DOI:10.3788/gzxb20235209.0930004

    Topics