Acta Photonica Sinica, Volume. 49, Issue 12, 42(2020)
Research on the Performance of Cantilever Low Frequency Vibration Sensor Based on Thin-diameter Excessively Tilted Fiber Grating
[1] VOHRA S T, JOHNSON G A, TODD M D. Distributed strain monitoring with arrays of fiber Bragg grating sensors on an in-Construction steel box-girder bridge[C], 83, 454-461(2000).
[2] ZHAO Z, LIU Z, TANG M. Robust in-fiber spatial interferometer using multicore fiber for vibration detection[J]. Optics Express, 26, 29629-29637(2018).
[3] CHENG Zhen-long, ZHAO Jian-lin, ZHOU Wang-min. A vibration sensor based on fiber Bragg grating Fabry-Perot cavity[J]. Acta Photonica Sinica, 39, 47-52(2010).
[4] TSUDA H. Fiber Bragg grating vibration-sensing system, insensitive to Bragg wavelength and employing fiber ring laser[J]. Optics Letters, 35, 2349-2351(2010).
[5] GUO T, SHANG L, RAN Y. Fiber-optic vector vibroscope[J]. Optics Letters, 37, 2703-2705(2012).
[6] RONG Q, QIAO X, GUO T. Orientation-dependent fiber-optic accelerometer based on grating inscription over fiber cladding[J]. Optics Letters, 39, 6616-6619(2014).
[7] TANAKA S, SOMATOMO H, WADA A. Fiber-optic mechanical vibration sensor using long-period fiber grating[J]. Japanese Journal of Applied Physics, 48, 07(2009).
[8] ZHOU K, ZHANG L, CHEN X. Optic sensors of high refractive-index responsivity and low thermal cross sensitivity that use fiber Bragg gratings of >80 tilted structures[J]. Optics Letters, 31, 1193-1195(2006).
[9] YAN Z, SUN Q, WANG C. Refractive index and temperature sensitivity characterization of excessively tilted fiber grating[J]. Optics Express, 25, 3336-3346(2017).
[10] CHEN X, ZHOU K, ZHANG L. In-fiber twist sensor based on a fiber Bragg grating with 81°tilted structure[J]. IEEE Photonics Technology Letters, 18, 2596-2598(2006).
[11] MOU C, ZHOU K, YAN Z. Liquid level sensor based on an excessively tilted fibre grating[J]. Optics Communications, 305, 271-275(2013).
[12] LUO Bin-bin, ZOU Wen-gen, ZHAO Ming-fu. pH sensor based on fiber grating with extremely large tilt angle and its sensitivity enhancement[J]. Acta Optica Sinica, 37, 113-120(2017).
[13] LU T, SUN Y, MORENO Y. Excessively tilted fiber grating-based vector magnetometer[J]. Optics Letters, 44, 2494-2497(2019).
[14] LUO B, YANG W, HU X. Study on vibration sensing performance of an equal strength cantilever beam based on an excessively tilted fiber grating[J]. Applied Optics, 57, 2128-2134(2018).
[16] LUO Bin-bin, XIE Lang, WANG Ya-jie. Performance optimization of excessively tilted fiber grating cantilever beam vibration sensor[J]. Acta Optica Sinica, 39, 0806006(2019).
[17] YAN Z, SUN Z, ZHOU K. Numerical and experimental analysis of sensitivity-enhanced RI sensor based on ExTFG in thin cladding fiber[J]. Journal of Lightwave Technology, 33, 3023-3027(2015).
[18] SHU X W, ZHANG L, BENNION I. Sensitivity characteristics of long-period fiber gratings[J]. Journal of Lightwave Technology, 20, 255-266(2002).
Get Citation
Copy Citation Text
Xue ZOU, Ou DENG, Bin-bin LUO, De-cao WU, Ming-fu ZHAO, Nian-bing ZHONG, Tao SONG, Shang-hai JIANG, Lang XIE, Peng LIU, En-hua LIU. Research on the Performance of Cantilever Low Frequency Vibration Sensor Based on Thin-diameter Excessively Tilted Fiber Grating[J]. Acta Photonica Sinica, 2020, 49(12): 42
Category: Fiber Optics and Optical Communications
Received: --
Accepted: --
Published Online: Mar. 11, 2021
The Author Email: Bin-bin LUO (luobinbin@cqut.edu.cn)