Laser & Optoelectronics Progress, Volume. 59, Issue 24, 2411004(2022)

Intelligent Photon Counting Single Pixel Micro-Imaging System

Yuanpeng Cai, Qiurong Yan*, Yaoming Yang, Yining Xiong, and Yongjian Zheng
Author Affiliations
  • School of Information Engineering, Nanchang University, Nanchang 330031, Jiangxi, China
  • show less
    Figures & Tables(10)
    Experimental system diagram. (a) Schematic diagram; (b) experimental setup
    Functional block diagram of Zynq platform
    Timing diagram of DMD deflection and photon counting synchronous control
    DFC-Net structure diagram
    Simulation experimental average PSNR values of DFC-Net, DR2-Net and TVAL3 in different sampling rates
    DFC-Net reconstruction results with different sampling rates (Zynq)
    DR2-Net reconstruction results with different sampling rates (PC)
    TVAL3 reconstruction results with different sampling rates (PC)
    Experimental results. (a) Reconstructed images; (b) MSE curve of reconstruction results under different number of measurements
    • Table 1. PSNR values of DFC-Net, DR2-Net and TVAL3 with different sampling rates

      View table

      Table 1. PSNR values of DFC-Net, DR2-Net and TVAL3 with different sampling rates

      MethodSR is 0.10SR is 0.15SR is 0.20SR is 0.25SR is 0.30
      DFC-Net16.029317.477720.470321.419622.9077
      DR2-Net18.954220.226623.217023.772125.3211
      TVAL315.622618.669523.124924.481425.2373
    Tools

    Get Citation

    Copy Citation Text

    Yuanpeng Cai, Qiurong Yan, Yaoming Yang, Yining Xiong, Yongjian Zheng. Intelligent Photon Counting Single Pixel Micro-Imaging System[J]. Laser & Optoelectronics Progress, 2022, 59(24): 2411004

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Imaging Systems

    Received: Sep. 26, 2021

    Accepted: Oct. 29, 2021

    Published Online: Jan. 11, 2023

    The Author Email: Yan Qiurong (yanqiurong@ncu.edu.cn)

    DOI:10.3788/LOP202259.2411004

    Topics