Laser & Optoelectronics Progress, Volume. 54, Issue 8, 83004(2017)

Leakage Detection of Vial Based on Tunable Diode Laser Absorption Spectroscopy

Wang Mingming1、*, Dai Weiguo2, Yang Huinan1, Chen Jun1, Su Mingxu1, and Cai Xiaoshu1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    References(23)

    [1] [1] Shi Weiqin, Lou Wei. The domestic medical lyophilizer development nearly fifteen years and trend expectation[J]. Drying Technology & Equipment, 2011, 9(1): 3-8.

    [2] [2] Liu Ping. Systems of vials automatic loading and unloading from freeze-dryer[J]. Technological Development of Enterprise, 2011, 30(9): 5-7.

    [3] [3] Miao Xianhua. Study of schering bottles measurement technology[J]. Modern Manufacturing Technology and Equipment, 2015(5): 49-51.

    [4] [4] Barresi A A, Pisano R, Fissore D, et al. Monitoring of the primary drying of a lyophilization process in vials[J]. Chemical Engineering & Processing, 2009, 48: 408-423.

    [5] [5] Yang Zongfang, Bai Jianyu. Vial size detection based on machine vision[J]. Computer Measurement & Control, 2016, 24(8): 63-66.

    [6] [6] Zhang Hanle, Mao Jianxu, Zhang Xiaolin. Research on automatic visual inspection method and system for defects of vials[J]. Computer Engineering and Applications, 2014, 50(19): 147-151.

    [7] [7] Yu Peiming, Huang Taikang. Discussion on treatment of deteriorated and contaminated drugs[J]. Chinese Pharmaceutical Affairs, 2007, 21(3): 160-161.

    [8] [8] Dolan S A, Felizardo G, Barnes S, et al. APIC position paper: safe injection, infusion, and medication vial practices in health care[J]. American Journal of Infection Control, 2016, 44: 750-757.

    [9] [9] Vertucci F J, Beatty R G. Apical leakage associated with retrofilling techniques:a dye study[J]. Journal of Endodontics, 1986, 12(8): 331-336.

    [10] [10] Sivaramakrishna V, Raspante F, Palaniappan S, et al. PET bottles seal quality testing using an on-line pressure differential detector[J]. Journal of Food Engineering, 2007, 80: 645-654.

    [11] [11] Fan Yue. Inspection for leakage of vials[J]. Heilongjiang Medicine Journal, 2014, 27(3): 593-595.

    [12] [12] Yang H, Greszik D, Dreier T, et al. Simultaneous measurement of liquid water film thickness and vapor temperature using near-infrared tunable diode laser spectroscopy[J]. Applied Physics B, 2010, 99: 385-390.

    [13] [13] Barbu T L, Vinogradov I, Durry G, et al. TDLAS a laser diode sensor for the in situ monitoring of H2O, CO2, and their isotopes in the Martian atmosphere[J]. Advances in Space Research, 2006, 38: 718-725.

    [15] [15] Jia Liangquan, Liu Wenqing, Kan Ruifeng, et al. Study on oxygen velocity measurement in wind tunnel by wavelength modulation-TDLAS technology[J]. Chinese J Lasers, 2015, 42(7): 0715001.

    [16] [16] Wang Yan, Zhang Rui. Photo detector characteristics effect on TDLAS gas detection[J]. Acta Optica Sinica, 2016, 36(2): 0230002.

    [19] [19] Li Fei, Yu Xilong, Chen Lihong, et al. Temperature and water vapour concentration measurements of CH4/air premixed flat flame based on TDLAS[J]. Journal of Experiments in Fluid Mechanics, 2009, 23(2): 40-44.

    [21] [21] Yang H, Guo X, Su M, et al. Novel method for simultaneous measurement of film thickness and mass fraction of urea-water solution[J]. Chinese Optics Letters, 2014, 12(12): 123102.

    [22] [22] Yang H, Guo X, Zhou W, et al. Investigation on liquid film of urea-water solutions with diode laser absorption spectroscopy[J]. Experiments in Fluids, 2015, 56: 73.

    Tools

    Get Citation

    Copy Citation Text

    Wang Mingming, Dai Weiguo, Yang Huinan, Chen Jun, Su Mingxu, Cai Xiaoshu. Leakage Detection of Vial Based on Tunable Diode Laser Absorption Spectroscopy[J]. Laser & Optoelectronics Progress, 2017, 54(8): 83004

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Spectroscopy

    Received: Feb. 28, 2017

    Accepted: --

    Published Online: Aug. 2, 2017

    The Author Email: Mingming Wang (18116473146@163.com)

    DOI:10.3788/lop54.083004

    Topics