Acta Photonica Sinica, Volume. 45, Issue 10, 1022001(2016)

Iris Acquiring Optical System Design with Wavefront Coding

ZHANG Ji-yan1,2、*, HUANG Yuan-qing2, and XIONG Fei-bing1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    References(19)

    [1] [1] DAUGMAN J G. How iris recognition works[J]. IEEE Transaction on Circuits and Systems for Video Technology, 2004, 14(1): 21-30.

    [2] [2] NARAYANSWAMY R, SILVERIRA P E X, SETTY H, et al. Extended depth-of-field iris recognition system for a workstation environment[C]. SPIE, 2005, 5779: 41-50.

    [3] [3] DAUGMAN J G. High confidence visual recognition of person by a test of statistical independence[J]. IEEE Transaction on PAMI, 1993, 15(1): 1148-1161.

    [4] [4] BARWICK D S. Increasing the information acquisition volume in iris recognition systems[J]. Applied Optics, 2008, 47(26): 4684-4691.

    [6] [6] LIN Bin, WANG Lin-fen, CAO Xiang-qun. Study of iris image capturing system for iris recognition[J]. Laser&Infrared, 2002, 32(5): 347-349.

    [7] [7] WANG Lin-feng, LIN Bin. A portable personnel verification system based on iris recognition technology[J]. Journal of Opto Electronics·Laser, 2001, 12(10): 1076-1078.

    [8] [8] YUAN Wei-qi, JI Shuang. Design of iris image acquisition system[J]. Instrument Technique and Sensor, 2009, 25(10-2): 21-23.

    [9] [9] VAN DER GRACHT J, PAUCA V P, SETTY H, et al. Iris recognition with enhanced depth-of-field image acquisition[C]. SPIE5438, Visual Information Processing XIII, Orlando, FL, USA, 2004: 120-129.

    [10] [10] NARAYANSWAMY R, JOHNSONG E, SILVEIRA P E X, et al. Extending the imaging volume for biometric iris recognition[J]. Applied Optics, 2005, 44(5): 701-712.

    [11] [11] DOWSKI E R, CATHEY W T. Extended depth of field through wave-front coding[J]. Applied Optics, 1995, 34(10): 1859-1866.

    [12] [12] APOULIS A. Ambiguity function in Fourier optics[J]. Journal of The Optical Society of America, 1974, 64(6): 779-788.

    [13] [13] SHERIF S, CATHEY W T, DOWSKI E R.Phase plate to extend the depth of field of incoherent hybrid imaging systems[J]. Applied Optics, 2004, 43(13): 2709-2721.

    [14] [14] FAN Zhi-gang, CHEN Shou-qian,Chang Hong, et al. Non-axial characteristics of strehl ratio of cubic phase mask in wavefront coding system[J]. Acta Optica Sinica, 2011, 31(6): 1-9.

    [16] [16] ZHAO T, YE Z, ZHANG W, et al. Field depth extension of 2D barcode scanner based on wavefront coding and Projection algorithm[C]. SPIE, 2007, 6837: 1-11.

    [17] [17] HSIEH S H, YANG H W , HUANG S H, et al. Biometric iris image acquisition system with wavefront coding technology[C]. SPIE, 2013, 8907: 890730.

    [18] [18] PRASAD S, TORGERSEN T C, PAUCA V P, et al. Engineering the pupil phase to improve image quality[C]. SPIE, 2003, 5108: 1-12.

    [19] [19] CASTRO A, OJEDA C J. Increased depth of field with phase-only filters: ambiguity function [C]. SPIE, 2005, 582: 1-11.

    CLP Journals

    [1] TAN Zheng, XIANG-LI Bin, L Qun-bo, FANG Yu, SUN Jian-ying, ZHAO Na. Optics/Digital Processing Co-design Method Based on Aberration Optional-correcting[J]. Acta Photonica Sinica, 2018, 47(5): 511001

    Tools

    Get Citation

    Copy Citation Text

    ZHANG Ji-yan, HUANG Yuan-qing, XIONG Fei-bing. Iris Acquiring Optical System Design with Wavefront Coding[J]. Acta Photonica Sinica, 2016, 45(10): 1022001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Apr. 11, 2016

    Accepted: --

    Published Online: Nov. 14, 2016

    The Author Email: Ji-yan ZHANG (jyzhang@xmut.edu.cn)

    DOI:10.3788/gzxb20164510.1022001

    Topics