Optics and Precision Engineering, Volume. 25, Issue 10, 2541(2017)

Combined radiometric calibration of ground-based large-aperture infrared photoelectric systems

LIU Jun-chi*... LI Hong-wen, WANG Jian-li, YIN Li-mei, LI Hong-zhuang and ZHAO Jin-yu |Show fewer author(s)
Author Affiliations
  • [in Chinese]
  • show less
    References(20)

    [1] [1] VIGIL M L, WITTE D J, LEVAN P D, et al.. Sensor suite for the advanced electro-optical system (AEOS) 3.6-m telescope[J]. SPIE, 1996, 2819: 151-169.

    [2] [2] PRITCHETT D G, HENDRICK R W, MOORE D K, et al.. AEOS radiometer system: a multichannel imaging radiometer[J]. SPIE, 1999, 3701: 206-213.

    [3] [3] SUN Z Y, CHANG S T, ZHU W. Radiometric calibration method for large aperture infrared system with broad dynamic range[J]. Applied Optics, 2015, 54(15): 4659-4666.

    [5] [5] SUN Z Y, CHANG S T, ZHU W. Radiation calibration method for infrared system with large aperture and broad dynamic range[J]. Acta Optica Sinica, 2015, 34(7): 0712006. (in Chinese)

    [6] [6] CHANG S T, ZHANG Y Y, SUN Z Y, et al.. Method to remove the effect of ambient temperature on radiometric calibration[J]. Applied Optics, 2014, 53(27): 6274-6279.

    [7] [7] TANG J, GAO X. Calibration method for infrared radiation characteristics measuring system of test range[J]. Infrared and Laser Engineering, 2006, 35(S1): 266-270. (in Chinese)

    [10] [10] LI X SH, REN J W, ZHANG L G, et al.. Research on a radiometric calibration device for a large aperture infrared opto-electric system on spot[J]. Journal of Optoelectronics·Laser, 2006, 17(2): 175-178. (in Chinese)

    [11] [11] COHEN M, WALKER R G, BARLOW M J, et al.. Spectral irradiance calibration in the infrared. I. Ground-based and IRAS broadband calibrations[J]. The Astronomical Journal, 1998, 104(4): 1650-1657.

    [12] [12] COHEN M, WALKER R G, CARTER B, et al.. Spectral irradiance calibration in the infrared. X. A self-consistent radiometric all-sky network of absolutely calibrated stellar spectra[J]. The Astronomical Journal, 1999, 117(4): 1864-1889.

    [13] [13] COHEN M, WHEATON W A, MEGEATH S T. Spectral irradiance calibration in the infrared. XIV. The absolute calibration of 2MASS[J]. The Astronomical Journal, 2003, 126(2): 1090-1096.

    [14] [14] LIU J CH, LI H W, WANG J L, et al.. Fast radiance calibration for ground-based large-aperture infrared opto-electric equipment[J]. Acta Optica Sinica, 2015, 35(3): 0301003. (in Chinese)

    [16] [16] LIU Y Q, LIU X Y. Research on technology of ground-based infrared radiation feature measurement for space target[J]. Acta Optica Sinica, 2014, 34(5): 0512003. (in Chinese)

    [18] [18] HUANG CH, WANG J J, GAO X, et al.. Application of infrared star catalog in ground-based infrared radiation measurement system[J]. Infrared and Laser Engineering, 2013, 42(11): 2901-2906. (in Chinese)

    [20] [20] CHANG S T, ZHANG Y Y, SUN Z Y, et al.. Radiation measurement method for infrared small targets[J]. Acta Optica Sinica, 2014, 34(5): 0504001. (in Chinese)

    Tools

    Get Citation

    Copy Citation Text

    LIU Jun-chi, LI Hong-wen, WANG Jian-li, YIN Li-mei, LI Hong-zhuang, ZHAO Jin-yu. Combined radiometric calibration of ground-based large-aperture infrared photoelectric systems[J]. Optics and Precision Engineering, 2017, 25(10): 2541

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: May. 27, 2017

    Accepted: --

    Published Online: Nov. 24, 2017

    The Author Email: Jun-chi LIU (liujunchi703@163.com)

    DOI:10.3788/ope.20172510.2541

    Topics