Acta Optica Sinica, Volume. 41, Issue 6, 0611002(2021)

Image Reconstruction of Incomplete CT Scanning Using a CAD Model

Haosong Yu1,2, Yongning Zou1,2、*, Zhibin Zhang1,2, Gongjie Yao1,2, and Rifeng Zhou1,2
Author Affiliations
  • 1Engineering Research Center of Industrial Computed Tomography Nondestructive Testing, Ministry of Education, Chongqing University, Chongqing 400044, China
  • 2College of Optoelectronic Engineering, Chongqing University, Chongqing 400044, China
  • show less
    Figures & Tables(18)
    Scanning diagram of limited angle CT
    CAD model of object and schematic of section. (a) CAD model; (b) section
    Image of acquisition process. (a) Pixel section; (b) attenuation coefficient image; (c) prior image
    Simulated images. (a) Include defects; (b) include defects and noise
    Projection data in the range of [1°,120°]
    Reconstructed images with different NTV. (a) 10; (b) 20; (c) 30; (d) 40
    PSNR and SSIM of images with different NTVreconstructed by SART+TVM+PRIOR algorithm
    Reconstructed images under different iterations. (a) 100; (b) 300; (c) 500
    PSNR and SSIM versus number of iterations. (a) PSNR; (b) SSIM
    3D model made by AutoCAD software. (a) Model 1; (b) model 2
    Software and hardware of 3D printing and real object. (a) Software interface; (b) printer; (c) object
    Microfocus CT scanner
    Flowchart of acquiring prior image
    CT images reconstructed in the range of [1°,150°] and [1°,120°], display window is [0,1]. (a) SART; (b) SART+PRIOR; (c) SART+TVM; (d) SART+TVM+PRIOR
    CT images reconstructed in the range of [1°, 150°] and [1°, 120°], display window is [0, 1]. (a) SART; (b) SART+PRIOR; (c) SART+TVM; (d) SART+TVM+PRIOR
    • Table 1. Quantitative index of reconstructed images with different NTV

      View table

      Table 1. Quantitative index of reconstructed images with different NTV

      NTVAigorithmRMSEPSNRSSIM
      10SART+TVM0.097619.120.9366
      SART+TVM+PRIOR0.061623.130.9787
      20SART+TVM0.095019.380.9403
      SART+TVM+PRIOR0.059223.460.9806
      30SART+TVM0.092819.560.9432
      SART+TVM+PRIOR0.057823.690.9818
      40SART+TVM0.090919.740.9456
      SART+TVM+PRIOR0.057123.790.9823
      50SART+TVM0.089019.930.9482
      SART+TVM+PRIOR0.056623.850.9826
    • Table 2. Quantitative index of image a and b

      View table

      Table 2. Quantitative index of image a and b

      ImageRMSEPSNRSSIM
      a0.057823.690.9818
      b0.053424.080.985
    • Table 3. Parameters of the scanning

      View table

      Table 3. Parameters of the scanning

      ParameterContent
      Voltage60 KV
      Current150 mA
      Focus size5 mm
      Source to detector distance800 mm
      Source to rotation distance440 mm
      Detector array length1024 pixel×1024 pixel
      Unit size0.2 mm×0.2 mm
      Center offset102.8 mm
      Translation modeEqul-distance
      Angle graduation1000
    Tools

    Get Citation

    Copy Citation Text

    Haosong Yu, Yongning Zou, Zhibin Zhang, Gongjie Yao, Rifeng Zhou. Image Reconstruction of Incomplete CT Scanning Using a CAD Model[J]. Acta Optica Sinica, 2021, 41(6): 0611002

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Imaging Systems

    Received: Aug. 4, 2020

    Accepted: Nov. 2, 2020

    Published Online: Apr. 7, 2021

    The Author Email: Zou Yongning (zynlxu @sina.com)

    DOI:10.3788/AOS202141.0611002