Infrared and Laser Engineering, Volume. 53, Issue 1, 20230371(2024)

Research on the error influence mechanism of infrared temperature measurement of turbine guide vanes with end walls

Yingni Zhai1, Zhijie Liang1、*, Xianlong Meng2, and Cunliang Liu2
Author Affiliations
  • 1Department of Mechanical and Electrical Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China
  • 2School of Power and Energy, Northwestern Polytechnical University, Xi'an 710072, China
  • show less
    Figures & Tables(15)
    Schematic diagram of infrared observation of turbine guide vanes
    Demonstration of calculation of surface angular coefficients of microelements
    Closed system composed of n isothermal surfaces
    Radiation heat transfer model between concentric spheres
    Structural model of turbine guide vane
    Schematic diagram of blade section
    Blade grid division
    Temperature and error distribution of blade wall with different inlet Radiant intensity
    Distribution of blade wall error along blade height with different inlet radiant intensity
    Distribution of blade wall temperature and error at different outlet radiant intensity
    Distribution of blade error along blade height for different outlet radiant intensity
    Wall temperature and error distribution of blades with different surface Emissivity
    Error distribution of blades with different surface Emissivity along blade height
    • Table 1. Boundary condition setting

      View table
      View in Article

      Table 1. Boundary condition setting

      Boundary conditionValues
      Total gas inlet pressure/MPa1.454
      Total gas inlettemperature/KNon-uniform total temperature
      Total pressure at cold flow inlet/MPa1.5
      Total temperature of cold flow inlet/K750
      Gas inlet turbulence25%
      Cold flow inlet turbulence5%
    • Table 2. Example number setting for multi parameter sensitivity analysis of guide vane radiation

      View table
      View in Article

      Table 2. Example number setting for multi parameter sensitivity analysis of guide vane radiation

      ExamplenumberEntrance temperature/KEmissivity of wallRadiation typeExport temperature/K
      114000.6Wall/Gas1400
      216000.6Wall/Gas1400
      318000.6Wall/Gas1400
      416000.6Wall1200
      516000.6Wall1600
      616000.8Wall1400
      716000.2Wall1400
    Tools

    Get Citation

    Copy Citation Text

    Yingni Zhai, Zhijie Liang, Xianlong Meng, Cunliang Liu. Research on the error influence mechanism of infrared temperature measurement of turbine guide vanes with end walls[J]. Infrared and Laser Engineering, 2024, 53(1): 20230371

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Jun. 19, 2023

    Accepted: --

    Published Online: Mar. 19, 2024

    The Author Email: Liang Zhijie (599486222@qq.com)

    DOI:10.3788/IRLA20230371

    Topics