Journal of Radiation Research and Radiation Processing, Volume. 42, Issue 1, 010602(2024)

Radiation monitoring and prediction analysis of 60Co irradiation device at the Hunan irradiation center

Hui SONG, Yong ZHANG*, Feng GUO, Chao DENG, and Wenge LI
Author Affiliations
  • Hunan Institute of Nuclear Agricultural Science and Space Mutation Breeding, Hunan Academy of Agricultural Sciences, Changsha 410125, China
  • show less
    Figures & Tables(11)
    Irradiated outdoor circumferential radiation level detection first layer of plane layout map
    Irradiated outdoor circumferential radiation level detection second layer of plane layout map
    Irradiated outdoor circumferential radiation level detection third layer of plane layout map
    X-ray gamma radiation dose rate at different monitoring points after low-sourcing
    X-ray gamma radiation dose rate at different monitoring points after up-sourcing
    Trends in individual doses received by radiation workers
    Variation trend of water quality index of source water well
    Trend diagram of measured values and predicted values
    • Table 1. Radiation monitoring program

      View table
      View in Article

      Table 1. Radiation monitoring program

      监测项目 Monitoring items监测点位 Monitoring quantities监测频次 Monitoring frequency
      工作场所 Work-place47每半年 Semiannual
      贮源水井水质 Water quality of well3每半年 Semiannual
      人员外照射 Personnel external exposure佩戴监测 Wear monitoring每季度 Quarter
    • Table 2. Model accuracy grade table

      View table
      View in Article

      Table 2. Model accuracy grade table

      模型精度等级

      Model accuracy class

      PC
      1级(好)Level 1 (good)0.95≤ PC≤0.35
      2级(合格)Level 2 (pass)0.80≤P<0.950.35<C≤0.50
      3级(勉强)Level 3 (barely)0.70≤P<0.800.50<C≤0.65
      4级(不合格)Level 4 (failed)P<0.700.65<C
    • Table 3. Residual error test table of GM(1,1) model

      View table
      View in Article

      Table 3. Residual error test table of GM(1,1) model

      序号

      Serial number

      实际值

      Actual value

      预测值

      Predicted value

      残差

      Residual error

      残差百分数 / %

      Residual percentage

      0.0730.0750.002-2.7
      0.0810.0780.0033.7
      0.0830.0820.0011.2
      0.0840.085-0.001-1.2
    Tools

    Get Citation

    Copy Citation Text

    Hui SONG, Yong ZHANG, Feng GUO, Chao DENG, Wenge LI. Radiation monitoring and prediction analysis of 60Co irradiation device at the Hunan irradiation center[J]. Journal of Radiation Research and Radiation Processing, 2024, 42(1): 010602

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Research Articles

    Received: Sep. 20, 2023

    Accepted: Nov. 30, 2023

    Published Online: Mar. 27, 2024

    The Author Email: ZHANG Yong (张勇)

    DOI:10.11889/j.1000-3436.2023-0080

    Topics