Optics and Precision Engineering, Volume. 21, Issue 7, 1659(2013)

Geometric calibration for half-cover scanning in circular cone-beam CT

ZHANG Feng*... JIANG Hua, YAN Bin*, WEI Xing and LI Lei |Show fewer author(s)
Author Affiliations
  • [in Chinese]
  • show less
    References(14)

    [1] [1] NOO F, CLACKDOYLE R, MENNESSIER C, et al.. Analytic method based on identification of ellipse parameters for scanner calibration in cone-beam tomography [J]. Physics in Medicine and Biology, 2000, 45(11): 3489-3508.

    [2] [2] CHO Y, MOSELEY D J, SIEWERDSEN J H, et al.. Accurate technique for complete geometric calibration of cone-beam computed tomography systems[J]. Medical Physics, 2005, 32(4): 968-983.

    [3] [3] WU D F, LI L, ZHANG L, et al.. Geometric calibration of cone-beam CT with a flat-panel detector[C]. IEEE Nuclear Science Symposium Conference, Valencia, Spain: NSS/MIC, 2011: 2952-2955.

    [4] [4] KYRIAKOU Y, LAPP R M, HILLEBRAND L, et al.. Simultaneous misalignment correction for approximate circular cone-beam computed tomography[J]. Physics in Medicine and Biology, 2008, 53(22): 6267-6289.

    [6] [6] FELDKAMP L, DAVIS L C , KRESS J W. Practical cone-beam algorithm [J]. Journal of the Optical Society America A, 1984, 1(6): 612-619.

    [7] [7] TUY H K. An inversion formula for cone-beam reconstruction [J]. SIAM Journal on Applied Mathematics, 1983, 43(3): 546-552.

    [11] [11] LI L, CHEN Z Q, ZHANG L, et al.. A cone-beam tomography system with a reduced size planar detector: a backprojection-filtration reconstruction algorithm as well as numerical and practical experiments[J]. Applied Radiation and Isotopes, 2007, 65(9): 1041-1047.

    [12] [12] OTSU N. A threshold selection method from gray-level histogram[J]. IEEE Transactions on Systems, Man and Cybernetic, 1979, 9(1): 62-66.

    [14] [14] GUO J Q, ZENG L, ZOU X B. An improved half-covered helical cone-beam CT reconstruction algorithm based on localized reconstruction filter[J]. Journal of X-Ray Science and Technology, 2011, 19(3): 293-312.

    CLP Journals

    [1] ZHOU Ling-hong, LI Han-wei, XU Yuan, LUO Yi-bin, QI Hong-liang. Geometry calibration for circular trajectory scanning in cone-beam CT[J]. Optics and Precision Engineering, 2014, 22(10): 2847

    [2] QIAO Kai, CHEN Jian, LI Zhong-guo, ZENG Lei, YAN Bin. Automatic printed circuit board wire detecting method of cone beam CT image[J]. Optics and Precision Engineering, 2016, 24(2): 413

    [3] ZHOU Qian-fei, LIU Jing-hong, WANG Xuan, SUN Ming-chao. Automatic correction of geometric distortion in aerial zoom squint imaging[J]. Optics and Precision Engineering, 2015, 23(10): 2927

    Tools

    Get Citation

    Copy Citation Text

    ZHANG Feng, JIANG Hua, YAN Bin*, WEI Xing, LI Lei. Geometric calibration for half-cover scanning in circular cone-beam CT[J]. Optics and Precision Engineering, 2013, 21(7): 1659

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Jan. 22, 2013

    Accepted: --

    Published Online: Aug. 5, 2013

    The Author Email: Feng ZHANG (xxgcxyzf2008@163.com)

    DOI:10.3788/ope.20132107.1659

    Topics