Acta Optica Sinica, Volume. 40, Issue 21, 2110003(2020)

CT Image Segmentation Method Combining Wavelet Transform and RSF Model

Jue Wang1,2、*, Xiuying Zhang1,2, Yufang Cai1,2, and Yanping Lu1,2
Author Affiliations
  • 1College of Optoelectronic Engineering, Chongqing University, Chongqing 400044, China
  • 2Engineering Research Center of Industrial Computed Tomography Nondestructive Testing, Ministry of Education, Chongqing University, Chongqing 400044, China
  • show less
    Figures & Tables(14)
    Diagram of blade structure
    Weak edge of CT image. (a) CT image of blade; (b) region of interest
    Flow chart of CT image measurement
    CT images. (a) Sample 1; (b) sample 2; (c) sample 3
    Comparison before and after wavelet transform. (a) Sample 1; (b) sample 2; (c) sample 3
    Grayscale comparison. (a) Sample 1; (b) sample 2; (c) sample 3
    Comparison of segmentation results
    Comparison of CV and RSF segmentation effects. (a)-(c) Segmentation results of CV and its local enlargement; (d)-(f) segmentation results of RSF and its local enlargement
    Segmentation results of RSF and CV combined wavelet transform on multi-cavity blade. (a) WT+CV; (b) WT+RSF
    CT image segmentation results of standard gauge blocks. (a) Original image; (b) CV; (c) WT+RSF
    • Table 1. Parameters of experiment

      View table

      Table 1. Parameters of experiment

      Sample No.CT systemX-ray energy /kVX-ray current /mAImage matrixSingle pixel size /mm
      1Linear array40011065×10650.1390
      2Linear array40011065×10650.1390
      3Planer array42011792×10240.0650
    • Table 2. Local average gradient of image

      View table

      Table 2. Local average gradient of image

      Sample No.Before wavelet transformAfter wavelet transform
      10.89940.9299
      20.67180.6893
      30.31940.4456
    • Table 3. Experimental parameter setting

      View table

      Table 3. Experimental parameter setting

      Sample No.λ1λ2μνσNiter
      11.01.010.045×255×25537000
      21.01.010.018×255×25536500
      31.01.010.045×255×25536000
    • Table 4. Test results of standard gauge blocks

      View table

      Table 4. Test results of standard gauge blocks

      No.Standard length /mmActual measurement length /mmAbsolute error /mmRelative error /%
      CVWT+RSFCVWT+RSFCVWT+RSF
      12020.127320.06620.12730.06620.63650.3310
      21010.080310.11670.08030.11670.80301.1670
      388.05708.02170.05700.02170.71250.2713
      466.03946.00300.03940.00300.65670.0500
      555.04955.00270.04950.00270.99000.0540
      644.11583.98620.11580.01382.89500.3450
      733.02292.98000.02290.02000.76330.6667
      822.02151.99540.02150.00461.0750-0.2300
      910.98801.00640.01200.0064-1.20000.6400
    Tools

    Get Citation

    Copy Citation Text

    Jue Wang, Xiuying Zhang, Yufang Cai, Yanping Lu. CT Image Segmentation Method Combining Wavelet Transform and RSF Model[J]. Acta Optica Sinica, 2020, 40(21): 2110003

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Image Processing

    Received: May. 29, 2020

    Accepted: Jul. 15, 2020

    Published Online: Oct. 17, 2020

    The Author Email: Wang Jue (wangjue@cqu.edu.cn)

    DOI:10.3788/AOS202040.2110003