Optics and Precision Engineering, Volume. 26, Issue 11, 2639(2018)

Fabrication and application of dual-wavelength infrared transmission-type interferometer

ZHAO Zhi-liang1,2、*, CHEN Li-hua2, ZHAO Zi-jia1, LIU Jie2, and LIU Min1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    References(16)

    [1] [1] CHEN J B, CHEN L, WANG Q, et al.. A large aperture phase-shifting CO2 laser interferometer [J]. Chinese Journal of Lasers, 1998, A25(1): 31-36.(in Chinese)

    [2] [2] VERMA K V, HAN B. Warpage measurement on dielectric rough surfaces of microelectronics device by far infrared Fizeau interferometry [J]. Journal of Electronic Packaging, 2000, 112(3): 227-232.

    [3] [3] WU Y Q, ZHANG Y D, ZHANG J. Design and fabrication of far-infrared Fizeau interferometer [C].Society of Photo-Optical Instrumentation Engineers, 2010, 7659: 765919.

    [5] [5] KWON O S, WYANT J C, HAYSLETT C R. Rough surface interferometry at 10.6μm [J]. Applied Optics, 1980, 19(11): 1862-1869.

    [6] [6] YUAN Q, GAO Z S, ZHU B, et al.. An infrared interferometer with a broadband wavelength channel [J]. Optics and Lasers in Engineering, 2013, 51: 1283-1290.

    [8] [8] HUANG W. Study on Thin Films Technology for Mid-Far-Infrared Laser Coatings[D]. Chengdu: Sichuan University, 2005.(in Chinese)

    [10] [10] PRETTYJOHNS K N, DEVORE S, DERENIAK, et al.. Direct phase measurement interferometer working at 3.8 μm [J]. Applied Optics, 1985, 24: 2211-2216.

    [11] [11] ZHU W H, CHEN L, ZHENG D H, et al.. Dynamic Fizeau interferometer based on the lateral displacements of the point sources [J]. Optics and Lasers in Engineering, 2017, 91: 216-220.

    [12] [12] EL-ZAIAT S Y, MISSOTTEN L, ENGELEN J. Radius of curvature measurement by Tyman-Greens interferometer [J]. Optics and Lasers in Engineering, 1991, 15: 203-208.

    [14] [14] ZHU M X, BAI F Z, GAN S M, et al.. Error compensation of four and five buckets wavefront extraction algorithms in phase-shifting interferometer [J]. Optik, 2013, 124: 5624-5627.

    CLP Journals

    [1] LU Qing-jie, LIU Wei, WEI Guang-yu, HAN Sen. Wavelength-tuned phase-shifting interference system based on optical power real-time feedback and synchronous calibration[J]. Optics and Precision Engineering, 2020, 28(4): 878

    [2] LU Qing-jie, LIU Wei, WEI Guang-yu, HAN Sen. Wavelength-tuned phase-shifting interference system based on optical power real-time feedback and synchronous calibration[J]. Optics and Precision Engineering, 2020, 28(4): 878

    Tools

    Get Citation

    Copy Citation Text

    ZHAO Zhi-liang, CHEN Li-hua, ZHAO Zi-jia, LIU Jie, LIU Min. Fabrication and application of dual-wavelength infrared transmission-type interferometer[J]. Optics and Precision Engineering, 2018, 26(11): 2639

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Feb. 10, 2018

    Accepted: --

    Published Online: Jan. 10, 2019

    The Author Email: ZHAO Zhi-liang (zzl_siom@163.com)

    DOI:10.3788/ope.20182611.2639

    Topics