Chinese Optics Letters, Volume. 18, Issue 8, 080201(2020)

Improving the NV generation efficiency by electron irradiation

Bowen Zhao1,2, Yang Dong1,2、*, Shaochun Zhang1,2, Xiangdong Chen1,2, Wei Zhu3, and Fangwen Sun1,2
Author Affiliations
  • 1CAS Key Laboratory of Quantum Information, University of Science and Technology of China, Hefei 230026, China
  • 2CAS Center for Excellence in Quantum Information and Quantum Physics, University of Science and Technology of China, Hefei 230026, China
  • 3Hefei National Laboratory for Physical Science at Microscale, Department of Physics, University of Science and Technology of China, Hefei 230026, China
  • show less
    Figures & Tables(9)
    Magnetic sensing system.
    PL saturation curves under different electron beam irradiation doses.
    PL counts with different electron beam irradiation doses and excitation intensities.
    Spectra of NV color centers with different electron beam irradiation doses.
    ODMR contrast of the samples with different electron beam irradiation doses.
    (a) XRD intensity of front side and (b) XRD rocking curves on both sides.
    • Table 1. PL Saturations of Different Samples

      View table
      View in Article

      Table 1. PL Saturations of Different Samples

      Electron Dose (×1016cm2)Isat(×108s1)αEnhancement
      02.07(0.07)0.03(1)1.00
      12.94(0.15)0.11(1)1.42
      28.44(0.51)0.21(1)4.01
      418.30(1.43)0.46(2)8.84
      838.06(2.18)0.80(4)18.39
      1644.49(3.77)0.99(6)21.49
    • Table 2. Decoherence Times for Different Samples

      View table
      View in Article

      Table 2. Decoherence Times for Different Samples

      Electron Dose (×1016cm2)T2* (ns)T2 (μs)T1 (ms)
      080(4)
      1310(20)75(2)2.6(2)
      2458(21)73(2)2.5(2)
      4313(53)125(5)3.7(4)
      8447(23)79(3)3.5(3)
      16377(60)77(4)2.3(4)
    • Table 3. Magnetic Field Measurement Sensitivity for DC and AC Magnetic Fields

      View table
      View in Article

      Table 3. Magnetic Field Measurement Sensitivity for DC and AC Magnetic Fields

      Electron Dose (×1016cm2)C(%)nηdc(nT/Hz1/2)ηac(nT/Hz1/2)
      04.7(1)49.7(2.5)7.59(36)
      15.5(1)94.8(4.7)38.12(1.91)3.85(16)
      24.5(1)229.8(11.5)24.61(1.13)3.06(12)
      43.3(2)402.9(20.1)30.67(2.85)2.41(14)
      82.8(1)822.2(41.1)21.18(1.02)2.50(14)
      161.6(1)929.9(46.5)38.67(3.09)4.25(27)
    Tools

    Get Citation

    Copy Citation Text

    Bowen Zhao, Yang Dong, Shaochun Zhang, Xiangdong Chen, Wei Zhu, Fangwen Sun, "Improving the NV generation efficiency by electron irradiation," Chin.Opt.Lett. 18, 080201 (2020)

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Atomic and Molecular Optics

    Received: Apr. 26, 2020

    Accepted: Jun. 23, 2020

    Posted: Jun. 28, 2020

    Published Online: Jul. 16, 2020

    The Author Email: Yang Dong (dongy13@ustc.edu.cn)