High Power Laser and Particle Beams, Volume. 31, Issue 7, 70007(2019)

Analysis of high-altitude electromagnetic effect models on power system

Chen Yuhao1、*, Xie Yanzhao1, Liu Minzhou1, Gao Chong2, Li Meng3, Gong Shaoyan2, and Zhou Jianhui2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • show less
    References(13)

    [1] [1] Nitsch D, Camp M, Sabath F, et al. Susceptibility of some electronic equipment to HPEM threats[J]. IEEE Trans Electromagn Compat, 2004, 46(3):380-389.

    [2] [2] Camp M, Gerth H, Garbe H, et al. Predicting the breakdown behavior of microcontrollers under EMP/UWB impact using a statistical analysis[J]. IEEE Trans Electromagn Compat, 2004, 46(3):368-379.

    [3] [3] Mnsson D, Thottappillil R, Nilsson T, et al. Susceptibility of civilian GPS receivers to electromagnetic radiation[J]. IEEE Trans Electromagn Compat, 2008, 50(2):434-437.

    [4] [4] Parfenov Y V, Zdoukhov L N, Shurupov A V, et al. Research of flashover of power line insulators due to high-voltage pulses with power ON and power OFF[J]. IEEE Trans Electromagn Compat, 2013, 55(3):467-474.

    [5] [5] Foster J S, Gjelde E, Graham W R, et al. Report of the commission to assess the threat to the United States from electromagnetic pulse (EMP) attack: Critical national infrastructures[R]. 2008.

    [10] [10] Berge J, Varma R K, Marti L. Laboratory validation of the relationship between geomagnetically induced current (GIC) and transformer absorbed reactive power[C]//Electrical Power and Energy Conference. 2011:491-495.

    [11] [11] Takasu N, Oshi T, Miyawaki F, et al. An experimental analysis of DC excitation of transformers by geomagnetically induced currents[J]. IEEE Trans Power Delivery, 1994, 9(4):1173-1182.

    [13] [13] Girgis R, Vedante K. Effects of GIC on power transformers and power systems[C]//2012 IEEE Transmission and Distribution Conference and Exposition. 2012:1-8.

    [14] [14] Foster J S, Gjelde E, Graham W R, et al. Report of the commission to assess the threat to the United States from electromagnetic pulse (EMP) attack. Volume 1: Executive report[R]. 2004.

    [16] [16] Florkowski M, Furgal J, Pajak P. Analysis of fast transient voltage distributions in transformer windings under different insulation conditions[J]. IEEE Trans Dielectrics and Electrical Insulation, 2012, 19(6):1991-1998.

    [17] [17] Sabath F. Classification of electromagnetic effects at system level[C]//Int Sympon Electromagn Compat. 2008.

    [18] [18] LiKejie, Xie Yanzhao, Chen Yuhao, et al. Multinomial regression model for the evaluation of multi-level effects caused by high-power electromagnetic environments[J]. IEEE Trans Electromagn Compat, 2019, 61(1):149-156.

    [19] [19] LiuYu, Han Feng, Wang Jianguo, et al. Vulnerability assessment of a multistate component for IEMI based on a Bayesian method[J]. IEEE Trans Electromagn Compat, 2019, 61(2):467-475.

    Tools

    Get Citation

    Copy Citation Text

    Chen Yuhao, Xie Yanzhao, Liu Minzhou, Gao Chong, Li Meng, Gong Shaoyan, Zhou Jianhui. Analysis of high-altitude electromagnetic effect models on power system[J]. High Power Laser and Particle Beams, 2019, 31(7): 70007

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: May. 24, 2019

    Accepted: --

    Published Online: Jul. 31, 2019

    The Author Email: Yuhao Chen (chenyuhao@stu.xjtu.edu.cn)

    DOI:10.11884/hplpb201931.190184

    Topics