Acta Optica Sinica, Volume. 38, Issue 3, 322001(2018)

Optical Design of Infrared Bispectrum Fourier Transform Imaging Spectrometer

Ji Yunbing1,2, Liang Jingqiu1、*, Liang Zhongzhu1, Lü Jinguang1, Qin Yuxin1, Wang Weibiao1, Tao Jin1, and Meng Dejia1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    Figures & Tables(16)
    Working principle of imaging spectrometer
    Tridimensional data cube
    Schematic diagram of coaxial three mirror system
    Schematic diagram of rectangular field of view
    Optimized structure diagram of the front telephoto system
    (a) Medium wave MTF; (b) long wave MTF
    (a) Structure diagram; (b) MTF curve; (c) spot diagram of medium wave post-imaging system
    (a) Structure diagram; (b) MTF curve; (c) spot diagram of long wave post-imaging system
    (a) Structure diagram; (b) MTF curve; (c) spot diagram of medium wave channel overall system
    (a) Structure diagram; (b) MTF curve; (c) spot diagram of long wave channel overall system
    • Table 1. Main specifications of the imaging spectrometer

      View table

      Table 1. Main specifications of the imaging spectrometer

      ParameterValue
      Wavelength coverage3.7-4.8 μm, 8-12 μm
      Spatial resolution0.3 m@2000 m
      Modulation transfer function (MTF)>0.5@17 lp/mm
    • Table 2. Parameters of the front telephoto system

      View table

      Table 2. Parameters of the front telephoto system

      ParameterValue
      Field of view1.5°
      Wavelength coverage3.7-4.8 μm, 8-12 μm
      Focal length1700 mm
      Image spare NA0.03
    • Table 3. Initial structural parameters of the front telephoto system

      View table

      Table 3. Initial structural parameters of the front telephoto system

      MirrorParameter
      Primaryr1=-3585.739, d1=-872.779, K1=-1.636
      Secondaryr2=-1456.625, d2=872.779, K2=-0.755
      Tertiaryr3=-1745.598, d3=-1090.974, K3=0.041
    • Table 4. Optimized structural parameters of the front telephoto system

      View table

      Table 4. Optimized structural parameters of the front telephoto system

      MirrorParameter
      Primaryr1=-3037.247, d1=-780, K1=-0.975
      Secondaryr2=-1262.266, d2=780, K2=-0.022
      Tertiaryr3=-1638.680, d3=-991.932, K3=0.084
    • Table 5. Parameters of medium wave post-imaging system

      View table

      Table 5. Parameters of medium wave post-imaging system

      ParameterValue
      Height of object22.5 mm
      Wavelength coverage3.7-4.8 μm
      Magnification0.24
      Object NA0.03
    • Table 6. Parameters of long wave post-imaging system

      View table

      Table 6. Parameters of long wave post-imaging system

      ParameterValue
      Height of object22.5 mm
      Wavelength coverage8-12 μm
      Magnification0.12
      Object NA0.03
    Tools

    Get Citation

    Copy Citation Text

    Ji Yunbing, Liang Jingqiu, Liang Zhongzhu, Lü Jinguang, Qin Yuxin, Wang Weibiao, Tao Jin, Meng Dejia. Optical Design of Infrared Bispectrum Fourier Transform Imaging Spectrometer[J]. Acta Optica Sinica, 2018, 38(3): 322001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Optical Design and Fabrication

    Received: Sep. 18, 2017

    Accepted: --

    Published Online: Mar. 20, 2018

    The Author Email: Jingqiu Liang (liangjq@ciomp.ac.cn)

    DOI:10.3788/AOS201838.0322001

    Topics