Acta Photonica Sinica, Volume. 52, Issue 3, 0352114(2023)

Remote Sensor System of Multi-component Gas Based on Wavelength Modulation Spectroscopy(Invited)

Yuan JIANG1,2, Ruijian ZHENG1,2, Xinke XU1,2, Longyang REN1,2, Gang ZHAO1,2, Yanting ZHAO1,2、*, and Weiguang MA1,2、**
Author Affiliations
  • 1State Key Laboratory of Quantum Optics and Quantum Optics Devices, Institute of Laser Spectroscopy, Shanxi University, Taiyuan 030006, China
  • 2Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan 030006, China
  • show less
    Figures & Tables(10)
    Intensity of absorption spectra of three gases in different wavelength ranges
    The system schematic diagram of experimental system
    Comparison of non-normalized and normalized 2f signals with light intensity at different distances
    Measurement results of methane DAS signal and 2f signal intensity
    2f signals for three gases with different integrated concentrations
    Calibration data for three gases with different integration concentrations
    Fluctuation of measured values for three gases at different remoting distances
    Measurement of lower detection limit
    • Table 1. Calibrated measurements of three gases at different integral concentrations

      View table
      View in Article

      Table 1. Calibrated measurements of three gases at different integral concentrations

      Integrated concentration/(ppm·m)Measured average concentration/(ppm·m)Standard deviationRelative error/%
      CH4
      1501547.42.72
      50049513.70.94
      1 1001 12730.22.48
      1 8001 82742.31.52
      3 5003 47643.10.67
      5 0005 08244.91.65
      7 0007 116110.11.66
      10 00010 229190.52.29
      NH3
      80081183.71.47
      1 5001 44886.53.45
      3 0002 96546.21.15
      5 0004 98173.60.38
      10 00010 054263.70.54
      20 00019 907525.60.46
      C2H2
      808411.14.39
      1501519.10.47
      30031515.65.12
      50054521.69.07
      1 00099671.10.35
      2 0002 02856.11.43
    • Table 2. Integrated concentration measurements for three gases at different remoting distances

      View table
      View in Article

      Table 2. Integrated concentration measurements for three gases at different remoting distances

      Distance/mMeasured average concentration/(ppm·m)Standard deviationRelative error/%
      CH4(3 500 ppm·m)
      103 49237.30.24
      203 43567.21.86
      303 38159.23.40
      403 17250.29.38
      NH3(5 000 ppm·m)
      104 98666.90.29
      204 98289.30.35
      304 86489.02.72
      404 79489.24.12
      C2H2(300 ppm·m)
      1031015.43.30
      2030817.52.70
      3029916.90.46
      4028418.35.43
    Tools

    Get Citation

    Copy Citation Text

    Yuan JIANG, Ruijian ZHENG, Xinke XU, Longyang REN, Gang ZHAO, Yanting ZHAO, Weiguang MA. Remote Sensor System of Multi-component Gas Based on Wavelength Modulation Spectroscopy(Invited)[J]. Acta Photonica Sinica, 2023, 52(3): 0352114

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Special Issue for Frontiers and Techniques of Laser Spectroscopy

    Received: Jun. 19, 2022

    Accepted: Jul. 27, 2022

    Published Online: Jun. 21, 2023

    The Author Email: ZHAO Yanting (zhaoyt@sxu.edu.cn), MA Weiguang (mwg@sxu.edu.cn)

    DOI:10.3788/gzxb20235203.0352114

    Topics