Optics and Precision Engineering, Volume. 19, Issue 11, 2709(2011)

Application of silicon pressure sensor to nerve root retractor

LIU Xing1,*... HUANG Qing-an1, QIN Ming1 and CHEN Hui2 |Show fewer author(s)
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    References(12)

    [1] [1] TAYLOR R, RYAN J, O'DONNELL R, et al.. The cost-effectiveness of spinal cord stimulation in the treatment of failed back surgery syndrome [J]. Clinical Journal of Pain, 2010, 26(6): 463-469.

    [2] [2] BOSNJAK R, MAKOVEC M. Neurophysiological monitoring of S1 root function during microsurgical posterior discectomy using H-Reflex and spinal nerve root potentials [J]. Spine, 2010, 35(4): 423-429.

    [3] [3] KELLEHER M, TIMLIN M, PERSAUD O, et al.. Success and failure of minimally invasive decompression for focal lumbar spinal stenosis in patients with and without deformity [J]. Spine, 2010, 35(19): E981-E987.

    [4] [4] PAPAVERO L, THIEL M, FRITZSCHE E, et al.. Lumbar spinal stenosis: prognostic factors for bilateral microsurgical decompression using a unilateral approach [J]. Neurosurgery, 2009, 65(6):182-187.

    [5] [5] PARK P, LEVEQUE J, MARCA F L, et al.. Dural closure using the u-clip in minimally invasive spinal tumor resection [J]. Journal of Spinal Disorders & Techniques, 2010, 23(7): 486-489.

    [6] [6] WOOD K, DEVINE J, FISCHER D, et al.. Vascular injury in elective anterior lumbosacral surgery [J]. Spine, 2010, 35(9S): S66-S75.

    [7] [7] GHARIB J, FARQUHAR A, MARTINELLI S, et al.. System and methods for performing neurophysiologic assessments with pressure monitoring: US,2007/0021682 A1[P]. 2007.

    [8] [8] CUI ZH M, BAO G F, ZHANG J B, et al.. Experimental application of auxometric nerve root retractor [J]. Journal of Clinical Rehabilitative Tissue Engineering Research, 2008,30(12): 5857-5860. (in Chinese)

    [9] [9] BRAU S A, SPOONAMORE M J, SNYDER L, et al.. Nerve monitoring changes related to iliac artery compressionduring anterior lumbar spine surgery [J].The Spine Journal, 2003, 3(5): 351-355.

    [10] [10] MA J X, WANG L D, WU Y H. Application of micro electro mechanical system on medicine and biology [J]. Opt. Precision Eng., 1996, 4(1): 1-6. (in Chinese)

    [12] [12] MATSUI H, KITAGAWA H, KAWAGUCHI Y, et al.. Physiologic changes of nerve root during posterior lumbar discectomy [J]. Spine, 1995, 20(6):654-659.

    Tools

    Get Citation

    Copy Citation Text

    LIU Xing, HUANG Qing-an, QIN Ming, CHEN Hui. Application of silicon pressure sensor to nerve root retractor[J]. Optics and Precision Engineering, 2011, 19(11): 2709

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Sep. 27, 2010

    Accepted: --

    Published Online: Dec. 5, 2011

    The Author Email: Xing LIU (xingliu@seu.edu.cn)

    DOI:10.3788/ope.20111911.2709

    Topics