Journal of Applied Optics, Volume. 44, Issue 2, 295(2023)

Compression and reconstruction of photon counting integral imaging

Yumin CUI1... Liju YIN1,*, Liguo SUI2, Hui ZHOU1 and Yulin DENG1 |Show fewer author(s)
Author Affiliations
  • 1School of Electrical and Electronic Engineering, Shandong University of Technology, Zibo 255049, China
  • 2Weifang Engineering Vocational College, Weifang 262500, China
  • show less
    Figures & Tables(15)
    Schematic of off-axis distributed sensing system
    Model of distributed compressed sensing theory
    Proposed distributed compression and reconstruction framework
    Secondary reconstruction framework of non-reference images
    Experimental platform of photon counting-based ODIS
    Experimental images
    Reconstruction results of different non-reference images at measurement rate of 0.3
    PSNR and SSIM values of GOP_1 at different measurement rates
    PSNR and SSIM values of GOP_2 at different measurement rates
    PSNR and SSIM values of GOP_3 at different measurement rates
    PSNR and SSIM values of GOP_4 at different measurement rates
    PSNR and SSIM values of GOP_5 at different measurement rates
    Reconstruction results of GOP_2 at measurement rates of 0.25 and 0.4
    • Table 1. PSNR and SSIM values for image reconstruction results at measurement rate of 0.3

      View table
      View in Article

      Table 1. PSNR and SSIM values for image reconstruction results at measurement rate of 0.3

      图像OMPJoint-OMPBCS-SPL本文算法
      PSNR/dBSSIMPSNR/dBSSIMPSNR/dBSSIMPSNR/dBSSIM
      GOP_124.38470.542927.07650.605330.19580.747031.00200.7972
      GOP_224.07550.523227.07650.639929.42620.706631.37350.8046
      GOP_327.12710.563329.69630.657831.38350.759933.24330.8280
      GOP_427.26660.563230.84250.668331.43130.733633.81060.8032
      GOP_524.27780.488527.14740.578329.55820.704432.51050.7830
      平均值25.42630.536228.36780.629930.39900.730332.38800.8032
      平均运行时间/s3.49085.91543.19564.0201
    • Table 2. Average PSNR and SSIM values of reconstruction image at different measurement rates

      View table
      View in Article

      Table 2. Average PSNR and SSIM values of reconstruction image at different measurement rates

      测量率OMPJoint-OMPBCS-SPL本文算法
      PSNR/dBSSIMPSNR/dBSSIMPSNR/dBSSIMPSNR/dBSSIM
      0.2022.07950.448624.88830.497226.27480.582228.53400.6651
      0.2523.94050.471526.54620.540628.38530.645330.86430.7515
      0.3025.42630.536228.36780.629930.39900.730332.38800.8032
      0.3527.34200.627531.53570.735932.72730.783634.96460.8473
      0.4028.93840.677634.29740.812235.10310.831836.89890.8856
      0.4531.16380.732636.63060.857136.59630.861138.92050.9047
      0.5033.69550.778339.12990.897438.02720.880940.75330.9237
      平均值27.51230.610331.62800.710032.50190.759334.76050.8259
    Tools

    Get Citation

    Copy Citation Text

    Yumin CUI, Liju YIN, Liguo SUI, Hui ZHOU, Yulin DENG. Compression and reconstruction of photon counting integral imaging[J]. Journal of Applied Optics, 2023, 44(2): 295

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Research Articles

    Received: Dec. 8, 2022

    Accepted: --

    Published Online: Apr. 14, 2023

    The Author Email: YIN Liju (Ljyin72@163.com)

    DOI:10.5768/JAO202344.0202001

    Topics