Optics and Precision Engineering, Volume. 20, Issue 6, 1159(2012)

Enhancement of field depth for projection-type integral imaging three-dimensional display based on small diverging angle

ZHANG Lei*... YANG Yong, ZHAO Xing, FANG Zhi-liang and YUAN Xiao-cong |Show fewer author(s)
Author Affiliations
  • [in Chinese]
  • show less
    References(15)

    [1] [1] LIPPMANN G. La photograhie integrale[J].Comptes Rendus Acad. Sci.,1908,146:446-451.

    [4] [4] JIANG W, WEI SH H. Display estimation and image restoration for reflection stereo vision [J]. Opt. Precision Eng., 2011,19(7):1702-1707. (in Chinese)

    [6] [6] WANG A H, WANG Q H, LI D H, et al.. Relationship between stereo depth and parallax image captured in stereoscopic display [J]. Opt. Precision Eng., 2009,38(1):433-438. (in Chinese)

    [7] [7] ANG A H, WANG Q H, LI D H, et al.. Keystone distortion rectification of parallax images captured by toed-in cameras [J]. Journal of Sichuan University(Engineering Science Edition),2011,43(2):72-75. (in Chinese)

    [8] [8] WANG Q H.3D Display Technology and Device[M]. Beijing:Science Press,2011.(in Chinese)

    [10] [10] PARK S G,SONG B S,MIN S W.Analysis of image visibility in projection-type integral imaging system without diffuser[J].J. Opt. Soc. Kor., 2010,14:121-126.

    [11] [11] KIM Y,PARK S G,MIN S W,et al..Projection-type integral imaging system using multiple elemental image layers[J].Appl. Opt.,2011,50:B18-B24.

    [12] [12] JANG J S,JAVIDI B.Large depth-of-focus time-multiplexed three-dimensional integral imaging by use of lenslets with nonuniform focal lengths and aperture size[J]. Opt. Lett.,2003,28:1924-1926.

    [13] [13] HONG J,PARK J H, JUNG S,et al..Depth-enhanced integral imaging by use of optical path control[J].Opt. Lett.,2004,29:1790-1792.

    [14] [14] KIM Y,PARK J H,CHOI H,et al..Depth-enhanced three-dimensional integral imaging by use of multilayered display devices[J].Appl. Opt.,2006,45:4334-4343.

    [15] [15] KIM Y,CHOI H, KIM J,et al..Depth-enhanced integral imaging display system with electrically variable image planes using polymer-dispersed liquid-crystal layers[J].Appl. Opt.,2007,46:3766-3773.

    CLP Journals

    [1] MENG Fan-fei, BU Jing. Design and fabrication for micro-lens array with high fill factor in integral imaging system[J]. Optics and Precision Engineering, 2017, 25(8): 2130

    [2] Liu Yao, Deng Huan, Luo Chenggao, Wang Qionghua. An Integral Imaging Three Dimensional Display Method Based on Aperture Stop Array[J]. Acta Optica Sinica, 2014, 34(9): 910004

    [3] HAN Li-xiang, HUA Wei, MA Jian-she, SU Ping. MEMS manufacture process of high precision quartz hologram lens[J]. Optics and Precision Engineering, 2015, 23(11): 3107

    Tools

    Get Citation

    Copy Citation Text

    ZHANG Lei, YANG Yong, ZHAO Xing, FANG Zhi-liang, YUAN Xiao-cong. Enhancement of field depth for projection-type integral imaging three-dimensional display based on small diverging angle[J]. Optics and Precision Engineering, 2012, 20(6): 1159

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Dec. 22, 2011

    Accepted: --

    Published Online: Jun. 25, 2012

    The Author Email: Lei ZHANG (mooni189@163.com)

    DOI:10.3788/ope.20122006.1159

    Topics