High Power Laser and Particle Beams, Volume. 33, Issue 8, 083002(2021)

Uncertainty prediction of crosstalk measurement for multi-conductor transmission lines

Liting Deng1... Longquan Zhong2, Qiang Liu3, Zihan Sun1, Liping Yan1,* and Xiang Zhao1 |Show fewer author(s)
Author Affiliations
  • 1Department of Electronic and Information Engineering, Sichuan University, Chengdu 610065, China
  • 2Institute of Applied Electronics, China Academy of Engineering Physics, Mianyang 621900, China
  • 3Institute of Applied Physics and Computational Mathematics, Beijing 100088, China
  • show less
    Figures & Tables(14)
    The model of three-conductor transmission line
    Three-conductor crosstalk sensitivity analysis results
    Effects of spacing and height on the sensitivity of NEXT
    Sample selection
    Upper and lower bound obtained using the SROM method
    Experimental system of cable crosstalk
    Consistency measurement result of single wire
    Comparison between measured and simulated results
    Diagram of three-conductor transmission line test results
    Test uncertainty of three-conductor transmission lines
    • Table 1. Statistical properties of the input variables

      View table
      View in Article

      Table 1. Statistical properties of the input variables

      mean(h) σ(h) COV(h) mean(d) σ(d) COV(d) mean(r) σ(r) COV(r) mean(R) σ(R) COV(R)
      1010.12020.10.40.040.15050.1
    • Table 2. Statistical properties of the input variables

      View table
      View in Article

      Table 2. Statistical properties of the input variables

      h/mm d/mm
      Mean51015152025
      $\sigma $0.511.51.522.5
      COV0.10.10.10.10.10.1
    • Table 3. 50 Ω SMA load resistance

      View table
      View in Article

      Table 3. 50 Ω SMA load resistance

      R1R2R3R4R5R6R7R8
      49.048.048.048.049.048.048.048.5
    • Table 4. Comparison of crosstalk between measured and simulated results

      View table
      View in Article

      Table 4. Comparison of crosstalk between measured and simulated results

      ρΔ/dB
      NEXT0.93541.108
      FEXT0.92190.7679
    Tools

    Get Citation

    Copy Citation Text

    Liting Deng, Longquan Zhong, Qiang Liu, Zihan Sun, Liping Yan, Xiang Zhao. Uncertainty prediction of crosstalk measurement for multi-conductor transmission lines[J]. High Power Laser and Particle Beams, 2021, 33(8): 083002

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: High Power Microwave Technology

    Received: Mar. 5, 2021

    Accepted: --

    Published Online: Sep. 3, 2021

    The Author Email: Yan Liping (liping_yan@scu.edu.cn)

    DOI:10.11884/HPLPB202133.210066

    Topics