Optics and Precision Engineering, Volume. 25, Issue 11, 2865(2017)

Hard X-ray imaging based on CCD and CsI scintillator

LU Bo*... WANG Yu-sa, YANG Yan-ji, CUI Wei-wei and CHEN Yong |Show fewer author(s)
Author Affiliations
  • [in Chinese]
  • show less
    References(18)

    [1] [1] SHORT A D, KEAY A, TUMER M J L. Performance of the XMM EPIC MOS CCD detectors [J]. SPIE, 1998,3445: 13-27.

    [2] [2] GARMIRE G P, BAUTZ M W, FORD P G, et al.. Advanced CCD imaging spectrometer (ACIS) instrument on the Chandra X-ray observatory [J]. SPIE, 2003, 4851: 28-44.

    [3] [3] TSUNEMI H, HAYASHIDA K, TSURU T G, et al.. Soft X-ray Imager (SXI) onboard ASTRO-H [J]. SPIE, 2016, 9905: 990510-1-990510-11.

    [4] [4] NAKAJIMA H, INOUE S, NAGINO R, et al.. Performance of front-end mixed-signal ASIC for onboard CCD camera[J]. SPIE, 2014, 9154: 91541C-1-91541C-7.

    [5] [5] ROBRADE J, eROSITA-nearby young stars in X-rays [EB/OL]. arXiv: 1510.01161 [astro-ph.SR]. 2015.

    [6] [6] MEIDINGER N, ANDRITSCHKE R, HALKER O, et al.. Systematic testing and results of X-ray CCDs developed for eROSITA and other applications [J]. SPIE, 2006, 6276: 627618-1-627618-11.

    [7] [7] TAWA N, MUKAI K, IKEGAMI K, et al.. Optimization of a scintillator-deposited charge-coupled device with Monte-Carlo simulation [J]. Nuclear Instruments and Methods in Physics Research A, 2007, 573: 119-121.

    [8] [8] KITAGUCHI T, BHALERAO V, COOK W R, et al.. Inflight performance and calibration of the NuSTAR CdZnTe pixel detectors [J]. SPIE, 2014, 9144: 91441R-1-91441R-7.

    [9] [9] LU B, CHEN Y, ZHU Y, et al.. Researches on a composite detector technique based on X-ray CCDs [C]. 29th National Symposium on Space Exploration, Lhasa, Tibet, 2016: 376-384.(in Chinese)

    [10] [10] LU B, CUI W W, WANG Y S, et al.. Design and optimization of the readout system for X-ray CCDs [J]. Chinese Physics C, 2012, 36(9): 846-850.

    [11] [11] KIM B J, CHA B K, JEON H, et al.. A study on spatial resolution of pixelated CsI(Tl) scintillator [J]. Nuclear Instruments and Methods in Physics Research A, 2007, 579: 205-207.

    [12] [12] YAO D, GU M. LIU X,et al.. Fabrication and performance of CsI(Tl) scintillation films with pixel-like columnar-matrix structure [J]. IEEE Transactions on Nuclear Science, 2015, 62(3): 699-703.

    [13] [13] SIMON M, ENGEL K J, MENSER B, et al.. X-ray imaging performance of scintillator-filled silicon pore arrays [J]. Medical Physics, 2008, 35(3): 968-981.

    [14] [14] HORMOZAN Y, YUN S H, SVENONIUS O, et al.. Towards high-resolution X-ray imaging using a structured scintillator [J]. IEEE Transactions on Nuclear Science, 2012, 59(1): 19-23.

    [15] [15] MIYATA E, TAWA N, MUKAI K, et al.. High resolution X-ray photon-counting detector with scintillator-deposited charge-coupled device [C]. IEEE Nuclear Science Symposium Conference Record, Rome, Italy, 2004: 1014-1018.

    [16] [16] YAO D, GU M. LIU X,et al.. Fabrication and performance of micron thick CsI(Tl) films for X-ray imaging application [J]. IEEE Transactions on Nuclear Science, 2016, 63(3): 1827-1831.

    [17] [17] ZHANG T C, YI F T, WANG B, et al.. Fabrication of micro pore optics with smooth sidewall using X-ray lithography [J]. Microsystem Technologies, 2014, 20(10): 2005-2010.

    [18] [18] SCHLOSSER D M, HUTH M, HARTMANN R, et al.. Direct and indirect signal detection of 122 keV photons with a novel detector combining a pnCCD and a CsI(Tl) scintillator [J]. Nuclear Instruments and Methods in Physics Research A, 2016, 805: 55-62.

    CLP Journals

    [1] WANG Qi, GAO Dang-zhong, MA Xiao-jun, XU Chun, ZHU Yi-ning, JIANG Kai, ZHANG Yuan-cheng, YANG Shi-di. High precision X-ray digital imaging of inertial confinement fusion capsules[J]. Optics and Precision Engineering, 2020, 28(2): 324

    [2] Jia HUO, Xiaofan ZHAO, Weiwei CUI, Yusa WANG, Hao WANG, Yong CHEN. Real-time X-ray imaging data acquisition system for pnCCD[J]. Optics and Precision Engineering, 2024, 32(21): 3166

    [3] WANG Qi, GAO Dang-zhong, TANG Xing, MA Xiao-jun, WANG Zong-wei. Precision measurement of X-ray optical thickness in capsules[J]. Optics and Precision Engineering, 2019, 27(5): 1039

    [4] CHEN Tian-xiang, GAO Na, LI Lin, CHEN Yong, XU Yu-peng, LU Fang-jun. Optical property characterization of optical blocking filters used in space X-ray survey[J]. Optics and Precision Engineering, 2019, 27(11): 2337

    [5] ZHAO Zi-jian, WANG Yu-sa, ZHANG Liu-yang, CHEN Can, MA Jia. Experiments and simulation of X-ray optical Wolter-I focusing mirror[J]. Optics and Precision Engineering, 2019, 27(11): 2330

    [6] Jia HUO, Xiaofan ZHAO, Weiwei CUI, Yusa WANG, Hao WANG, Yong CHEN. Real-time X-ray imaging data acquisition system for pnCCD[J]. Optics and Precision Engineering, 2024, 32(21): 3166

    Tools

    Get Citation

    Copy Citation Text

    LU Bo, WANG Yu-sa, YANG Yan-ji, CUI Wei-wei, CHEN Yong. Hard X-ray imaging based on CCD and CsI scintillator[J]. Optics and Precision Engineering, 2017, 25(11): 2865

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Dec. 9, 2016

    Accepted: --

    Published Online: Jan. 17, 2018

    The Author Email: Bo LU (luboihep@outlook.com)

    DOI:10.3788/ope.20172511.2865

    Topics