Acta Photonica Sinica, Volume. 44, Issue 3, 312003(2015)

Research on Generating Device of Infinite Low Light Level Weapon Sight Target Simulation

XIAO Zuo-jiang1、*, GUO Xiao-xue2, ZHU Hai-bin3, XU Zhi-gang3, and AN Zhi-yong2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • show less
    References(18)

    [2] [2] GABER L.Optical sight system with wide range of shooting distances: US, 6, 487, 809 B1[P], 2002-12-3.

    [3] [3] HIDEKI K. Illumination optical system, illumination optical apparatus, exposure apparatus, and device manufacturing method: US, 20, 090, 040, 493 A1 [P], 2009-2-12.

    [4] [4] BIBTEX R E. Optical system for generating illumination strip: CN, 1, 957, 247 B [P], 2005-3-15.

    [5] [5] GAO You-tang, QIU Ya-feng, TIAN Si, et al. Mechanism analysis of zero displacement movement of LLL sight device based on vibration experimental condition[J]. Acta Armamentaria, 2008, 29(9): 1074-1077.

    [6] [6] ZHONG Xing, ZHANG Yuan, JIN Guang. Illumination uniformity optimization of wide-viewing-field optical system[J]. Acta Optica Sinica. 2012, 3(3): 217-222.

    [7] [7] SHEN Xiang-heng, YANG Liang, HE Geng-xian, et al. Measurement of image plane illumination non-uniformity of optical system in photoelectric equipment[J]. Optics and Precision Engineering, 2008, 16(12): 2513-2536.

    [8] [8] WANG Li, HE Geng-xian, SHEN Xiang-heng. A system for examining the image planes’ illumination non-uniformity of image forming system on photoelectric measuring equipment using CCD[J]. Optoelectronic Technology, 2008, 28(3): 212-215.

    [9] [9] YANG Lei. Study on the low-light level stress source system of low-light level night vision device testing equipment [D]. Changchun: Changchun university of Science and Technology, 2014.

    [11] [11] YE Yuan-long, WU Xiao-rong. Simulation of low-light-level condition in laboratory[J]. Laser & Infrared, 2006, 35(12): 942-943.

    [14] [14] LIU Hong-xing, REN Jian-wei, LI Xian-sheng, et al. Radiometric characteristics simulation of large aperture integrating sphere based on LightTools[J]. Infrared and Laser Engineering, 2013, 42(4): 960-965.

    [15] [15] WANG Gao-ming, GUO Cheng, ZHANG Liang-liang, et al. Simulation of the light energy uniformity of integrating sphere based on Monte Carlo method[J]. Laser & Infrared, 2009, 39(1): 67-69.

    [16] [16] SU Cheng-zhi, CAO Guo-hua, XU Hong-ji. Relationship analysis of output illuminance of integrating sphere and incident beam geometry[J]. Laser & Infrared, 2010, 40(2): 195-199.

    [17] [17] JERNSHJ K D, HASSING S. Analysis of reflectance and transmittance measurements on absorbing and scattering small samples using a modified integrating sphere setup[J]. Applied Spectroscopy, 2009, 63(8): 879-888.

    [18] [18] MCKEE G, PAL S, SETH H, et al. Design and characterization of a large area uniform radiance source for calibration of a remote sensing imaging system[C]. SPIE, 2007, 6677: 1-10.

    [20] [20] LUCKE R L. Lambertian radiance and transmission of an integrating sphere[J]. Applied Optics, 2007, 46(28): 6966-6970.

    CLP Journals

    [1] ZHENG Shao-lin, WANG Xia, JIN Wei-qi, BAI Xiao-feng. Research of Night Sky Radiation Spectral Matching Method Based on Genetic Algorithm[J]. Acta Photonica Sinica, 2016, 45(3): 330002

    Tools

    Get Citation

    Copy Citation Text

    XIAO Zuo-jiang, GUO Xiao-xue, ZHU Hai-bin, XU Zhi-gang, AN Zhi-yong. Research on Generating Device of Infinite Low Light Level Weapon Sight Target Simulation[J]. Acta Photonica Sinica, 2015, 44(3): 312003

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Jul. 11, 2014

    Accepted: --

    Published Online: Apr. 14, 2015

    The Author Email: Zuo-jiang XIAO (xiao2706@163.com)

    DOI:10.3788/gzxb20154403.0312003

    Topics