Optoelectronics Letters, Volume. 8, Issue 2, 81(2012)

Porous silicon biosensor for detection of variable domain of heavy-chain of HCAb antibody

Hong-yan ZHANG1, Xiao-yi LU2, Zhen-hong JIA3、*, Jiang-wei LI4, and Fu-chun ZHANG4
Author Affiliations
  • 1School of Physical Science and Technology, Xinjiang University, Urumqi 830046, China
  • 2Postdoctoral Station of Computer Science and Technology, Xinjiang University, Urumqi 830046, China
  • 3College of Information Science and Engineering, Xinjiang University, Urumqi 830046, China
  • 4Key Laboratory of Xinjiang Biological Resources and Gene Engineering, College of Life Sciences and Technology,Xinjiang University, Urumqi 830046, China
  • show less
    References(13)

    [1] [1] S. Muyldermans, T. N. Baral, V. Cortez Retamozzo, P. De Baetselier, E. De Genst, J. Kinne, H. Leonhardt, S. Magez, V. K. Nguyen, H. Revets, U. Rothbauer, B. Stijlemans, S. Tillib, U. Wernery, L. Wyns, Gh. Hassanzadeh-Ghassabeh and D. Saerens, Veterinary Immunology and Immunopathology 128, 178 (2009).

    [2] [2] R. H. J. Van der Linden, L. G. J. Frenken, B. de Geus, M. M. Harmsen, R. C. Ruuls, W. Stok, L. de Ron, S. Wilson, P. Davis and C. T. Verrips, Biochimica et Biophysica Acta 1431, 37 (1999).

    [3] [3] Erwin De Genst, Karen Silence, Klaas Decanniere, Katja Conrath, Remy Loris, J rg Kinne, Serge Muyldermans and Lode Wyns, Proc Natl Acad Sci 103, 4586 (2006).

    [4] [4] Erwin De Genst, Dirk Saerens, Serge Muyldermans and Katja Conrath, Developmental and Comparative Immunology 30, 187 (2006).

    [5] [5] Xiaoyi Lv, Jiaqing Mo, Tao Jiang, Furu Zhong, Zhenhong Jia, Jiangwei Li and Fuchun Zhang, Applied Surface Science 257, 1906 (2011).

    [6] [6] Lisa M. Bonanno, Tai C. Kwong and Lisa A. DeLouise, Analytical Chemistry Techniques 82, 9711 (2010).

    [7] [7] Tao Jiang, Jiaqing Mo, Xiaoyi Lu, Pengfei Yan, Zhenhong Jia, Jiangwei Li and Fuchun Zhang, Chinese Optics Letters 9, 022801 (2011).

    [8] [8] LI Rui, TU Yi-xian, LI Chen-chen, LU .. Xiao-yi, JIA Zhenhong and ZHANG Fu-chun, Journal of Optoelectronics Laser 21, 1111 (2010). (in Chinese)

    [9] [9] XIANG Mei, JIA Zhen-hong, LU .. Xiao-yi and ZHONG Furu, Journal of Optoelectronics Laser 22, 1200 (2011). (in Chinese)

    [10] [10] LV Xiao-yi, MO Jia-qing, TU Yi-xian, ZHONG Fu-ru, JIANG Tao, JIA Zhen-hong, LI Jiang-wei and ZHANG Fu-chun, Optoelectronics Letters 6, 314 (2010).

    [11] [11] Guoguang Rong and Sharon M. Weiss, Phys. Status Solidi A 206, 1365 (2009).

    [12] [12] Huimin Ouyang, Marc Christophersen, Romain Viard, Benjamin L. Miller and Philipper M. Fauchet, Advanced Functional Materials 15, 1851 (2005).

    [13] [13] Guoguang Rong, Ali Najmaie, John E. Sipe and Sharon M. Weiss, Biosensors and Bioelectronics 23, 1572 (2008).

    Tools

    Get Citation

    Copy Citation Text

    ZHANG Hong-yan, LU Xiao-yi, JIA Zhen-hong, LI Jiang-wei, ZHANG Fu-chun. Porous silicon biosensor for detection of variable domain of heavy-chain of HCAb antibody[J]. Optoelectronics Letters, 2012, 8(2): 81

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Oct. 8, 2011

    Accepted: --

    Published Online: Jul. 12, 2017

    The Author Email: Zhen-hong JIA (jzhh@xju.edu.cn)

    DOI:10.1007/s11801-012-1140-1

    Topics