Matter and Radiation at Extremes, Volume. 6, Issue 1, 014403(2021)
Experiments and simulations of isochorically heated warm dense carbon foam at the Texas Petawatt Laser
Fig. 1. Schematic of experiment. The short-pulse Texas Petawatt Laser (TPWL) accelerates protons off the first target, and the proton beam deposits energy and heats the second target (package). The second target emits blackbody radiation that is measured by the streaked optical pyrometer (SOP), while the energies of the protons that are not stopped in the package are measured by the Thomson parabola spectrometer (TPS). Adapted with permission from Roycroft
Fig. 2. Layout of experiment inside TPWL vacuum chamber. The target normal sheath acceleration (TNSA) protons that pass through the target are diagnosed by the TPS, while blackbody radiation from the target is captured and imaged onto the slit of the SOP.
Fig. 3. Microscope image of a mounted target. The gold foil is glued to the far side of the stalk. A heating package would be glued to the near side to create the necessary 300-
Fig. 4. (a) Expected brightness temperature as a function of streak-camera counts, calculated from blackbody formula and calibration for optics transmission and streak-camera settings. The streak camera saturates at 4095 counts, and we attempt to run the experiment at a setting where the maximum brightness temperature occurs near but below the saturation point. The dashed red lines are the upper and lower bounds for the brightness temperature based on the measurement uncertainties. (b) Streak-camera image converted from counts to brightness temperature (shot 11 441; package: 10-
Fig. 5. (a) Assumed spectrum, (b) dE/dX, and (c) fraction of spectrum stopped in each zone for sample proton spectra, all for shot 11 477. The package is 100-
Fig. 6. (a) Density profiles at 0 ps, 100 ps, and 500 ps for a sample aluminum-foil simulation (shot 9626). (b) Temperature profiles at 0 ps, 100 ps, and 500 ps for the same simulation as in (a), along with vertical lines showing the location of the 400-nm critical density at 100 ps and 500 ps.
Fig. 7. (a) Density profiles at 0 ps, 100 ps, and 500 ps for a sample CRF simulation (shot 11 477). (b) Temperature profiles at 0 ps, 100 ps, and 500 ps for the same simulation as in (a).
Fig. 8. (a) Material temperature and resulting optical depth for sample CRF simulation (shot 11 477) at 0 ps. (b) Material temperature and resulting optical depth for the same simulation at 500 ps.
Fig. 9. Post-processing of simulation of 10-
Fig. 10. (a) SOP lineout and three xRAGE simulations for shot 11 477, which was hotter and had less noise on the SOP than shot 11 485, shown in (b). The calculations are shown with an energy ramp and without (simply adding all of the energy at the starting point). The laser-to-ion-beam energy conversion efficiency is shown for both the cutoff and exponential-fit spectra.
Fig. 11. Models of warm and hot DQ atmosphere temperature and density, plotted alongside the same parameters in the xRAGE CRF simulations. The hot DQ models have a pure carbon composition, while the warm DQ models have
|
Get Citation
Copy Citation Text
R. Roycroft, P. A. Bradley, E. McCary, B. Bowers, H. Smith, G. M. Dyer, B. J. Albright, S. Blouin, P. Hakel, H. J. Quevedo, E. L. Vold, L. Yin, B. M. Hegelich. Experiments and simulations of isochorically heated warm dense carbon foam at the Texas Petawatt Laser[J]. Matter and Radiation at Extremes, 2021, 6(1): 014403