Optics and Precision Engineering, Volume. 21, Issue 2, 522(2013)

Self-calibration of precise vision-based printing equipment

LIANG Jing-lun*... CHEN Jia-zhao, Mo Jing-hui, KUANG Yong-cong and ZHANG Xian-min |Show fewer author(s)
Author Affiliations
  • [in Chinese]
  • show less
    References(16)

    [1] [1] PAN J, STORER R, SALLADE R, et al.. Critical variables of solder paste stencil printing for micro-BGA and fine-pitch QFP [J]. IEEE Trans. on Electron. Pack., 2004,27(2):125-132.

    [2] [2] JU M, LEE Y, LEE J, et al.. Double screen printed metallization of crystalline silicon solar cells as low as 30 μm metal line width for mass production[J]. Sol. Energ. Mat. Sol. C., 2012, 100: 204-208.

    [3] [3] YU A, BONEV I, ZSOMBOR-MURRAY P. New XY-Theta positioning table with partially decoupled parallel kinematics[C]. Proceeding of the IEEE Int. Symp. On Ind. Electron., Montreal, QC, Canada: ISIE, 2006:3108-3112.

    [4] [4] GAO M, LI T M, TANG X Q. Calibration experiment research of parallel kinematics machine with a few degrees[J]. Chinese J. of Mech. Eng., 2003, 39(9):118-122. (in Chinese)

    [5] [5] JOUBAIR A, SLAMNI M, BONEV I. A novel XY-Theta precision table and a geometric procedure for its kinematic calibration[J]. Robot. Cim.-Int. Manuf., 2012, 28: 57-65.

    [6] [6] CHANG P, WANG J S, LI T M, et al.. Step kinematic calibration of a 3-DOF planar parallel kinematic machine tool[J]. Sci. China Ser. E-Tech. Sci., 2008, 51(12): 2155-2167.

    [7] [7] HE X M DING H SH, FU T, et al.. Review on kinematic calibration of parallel kinematic machine[J]. Mach. Tool & Hydraulics,2004, 10:9-11. (in Chinese)

    [8] [8] ZOU H, NOTASH L. Discussion on the camera-aided calibration of parallel manipulators[C]. Proceeding of CCToMM Symp. Mech. Mach., and Mechatron., Saint-Hubert, QC, Canada: CD-ROM, 2001:1-2.

    [9] [9] LIANG J L, KUANG Y C, CHEN J Z, et al.. A novel XY-Theta alignment stage for screen printing and its accuracy analysis[C]. Proceeding of the IEEE Int. Conf. on Mech. and Autom., Chengdu, China: ICMA, 2012:1352-1357.

    [10] [10] ZHANG X M, KUANG Y C, LU SH L, et al.. A L type double cameras image acquisition device for automatic screen printer. China:ZL20060123893.4[P].2007-05-30.

    [11] [11] MERLET J-P. Direct kinematic of planar parallel manipulators[C]. Proceeding of the IEEE Int. Conf. on Robot. and Autom., Minneapolis, USA: ICRA, 1994:3744-3749.

    [12] [12] BRAND P, MOHR R. Accuracy in iamge measure[C]. Proceeding of SPIE Conf. Videometrics III, Vol. 2350, Boston, Ma, USA, 1994: 218-228.

    [13] [13] WANG J M, PU ZH B, ZHAO H, et al.. A new method for calibrating 2-D image measuring systems[J]. J. of Harbin Institute of Technology, 2000, 32(3):37-41. (in Chinese)

    [15] [15] LIANG J L, ZHANG X M, MO J H. Accuracy analysis and calibration of a XY-Theta parallel stage[J]. J. of South China University of Technology, 2012,11. (in Chinese)

    [16] [16] Manipulating industrial robots—performance criteria and related test methods, ISO 9283, 1998.

    Tools

    Get Citation

    Copy Citation Text

    LIANG Jing-lun, CHEN Jia-zhao, Mo Jing-hui, KUANG Yong-cong, ZHANG Xian-min. Self-calibration of precise vision-based printing equipment[J]. Optics and Precision Engineering, 2013, 21(2): 522

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Dec. 19, 2012

    Accepted: --

    Published Online: Feb. 26, 2013

    The Author Email: Jing-lun LIANG (mejlliang@foxmail.com)

    DOI:10.3788/ope.20132102.0522

    Topics