Chinese Optics Letters, Volume. 13, Issue 8, 082801(2015)

Reflection-type infrared biosensor based on surface plasmonics in graphene ribbon arrays

Wei Wei1,2,3,4、*, Jinpeng Nong1,2, Linlong Tang3,4, Guiwen Zhang1,2, Xiao Jiang1,2, and Yong Zhu1,2,4
Author Affiliations
  • 1Key Laboratory of Optoelectronic Technology & Systems, Ministry of Education of China, Chongqing University, Chongqing 400044, China
  • 2College of Optoelectronic Engineering, Chongqing University, Chongqing 400044, China
  • 3Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 401122, China
  • 4Chongqing Engineering Research Center of Graphene Film Manufacturing, Chongqing 401329, China
  • show less
    Figures & Tables(6)
    (a) Schematic of the biosensor based on graphene plasmonics and (b) the temporal coupled theory description of the coupling among the incident light, reflected light and the device.
    (a) Calculated GPs mode pattern when Λ=200 nm and W=100 nm and (b) reflection spectra with sensing medium change from air to cell protein (n=1.37) and to double-stranded DNA (n=1.53).
    (a) Simulated reflection spectra with varying τ when T=800 nm. (b) Resonant reflectance and FWHM extracted from the reflection spectra with varying τ. (c) Calculated FOM as a function of τ.
    (a) Simulated reflection spectra with varying T when τ=0.8 ps. (b) Resonant reflectance and FWHM extracted from the reflection spectra with varying T. (c) Calculated FOM as a function of T.
    (a) Reflectance mapping with varying wavelength of incident light and Fermi energy level when T=400 nm and τ=0.8 ps. (b) The extracted reflection spectra with varying Fermi energy level of graphene from 0.2 to 0.6 eV. (c) Comparison of the FOM of the reflection-type and the transmission-type biosensors with varying Fermi energy level.
    Comparison of the FOM of the reflection-type and the transmission-type biosensors with varying width (a) for a fixed Λ=200 nm and period (b) for a fixed occupation ratio of 50%.
    Tools

    Get Citation

    Copy Citation Text

    Wei Wei, Jinpeng Nong, Linlong Tang, Guiwen Zhang, Xiao Jiang, Yong Zhu. Reflection-type infrared biosensor based on surface plasmonics in graphene ribbon arrays[J]. Chinese Optics Letters, 2015, 13(8): 082801

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Remote Sensing and Sensors

    Received: Apr. 5, 2015

    Accepted: Jun. 8, 2015

    Published Online: Sep. 14, 2018

    The Author Email: Wei Wei (wwei@cqu.edu.cn)

    DOI:10.3788/COL201513.082801

    Topics