Infrared and Laser Engineering, Volume. 51, Issue 4, 20210496(2022)

Analysis and elimination of adhesive bonding force of flexible supported space mirror

Yongjian Wu1...2, Yong Liu1,2, and Xin Sun12 |Show fewer author(s)
Author Affiliations
  • 1Beijing Institute of Space Mechanics & Electricity, Beijing 100094, China
  • 2Beijing Key Laboratory of Advanced Optical Remote Sensing Technology, Beijing 100094, China
  • show less
    Figures & Tables(10)
    Secondary mirror assembly
    Support structure of secondary mirror
    Support structure and the corresponding finite element model
    • Table 1. Parameters of material performance

      View table
      View in Article

      Table 1. Parameters of material performance

      ParameterMirrorGluePadBipod rod
      MaterialULERTVInvar 4J32B TC4R
      Density/103 kg·m−32.211.508.874.45
      Modulus/GPa673.68114110
      Coefficient of thermal expansion/10−6 K−10.032520.039.0
    • Table 2. Analysis of adhesive curing

      View table
      View in Article

      Table 2. Analysis of adhesive curing

      Glue spot/mmShape of surfaceDeformation
      1RMS<0.001λ
    • Table 3. Temperature effect analysis

      View table
      View in Article

      Table 3. Temperature effect analysis

      ConditionShape of surfaceDeformation
      2 ℃ temperature riseRMS<0.001λ
    • Table 4. Influence of adhesive curing

      View table
      View in Article

      Table 4. Influence of adhesive curing

      ConditionShape of surfaceDeformation
      Without padRMS=0.012λ
      With padRMS=0.013λ
    • Table 5. Effect of vacuum degassing

      View table
      View in Article

      Table 5. Effect of vacuum degassing

      ConditionShape of surfaceDeformation
      Outgassing experimentRMS=0.020λ
    • Table 6. Stress relieving vibration condition and effects

      View table
      View in Article

      Table 6. Stress relieving vibration condition and effects

      ConditionShape of surfaceDeformation
      Total root mean square of 9 grms RMS=0.019λ
    • Table 7. Hot soak test and its effects

      View table
      View in Article

      Table 7. Hot soak test and its effects

      ConditionShape of surfaceDeformation
      40 ℃ (72 h)RMS=0.015λ
      60 ℃ (72 h)RMS=0.014λ
    Tools

    Get Citation

    Copy Citation Text

    Yongjian Wu, Yong Liu, Xin Sun. Analysis and elimination of adhesive bonding force of flexible supported space mirror[J]. Infrared and Laser Engineering, 2022, 51(4): 20210496

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Optical design

    Received: Jul. 19, 2021

    Accepted: --

    Published Online: May. 18, 2022

    The Author Email:

    DOI:10.3788/IRLA20210496

    Topics