Optics and Precision Engineering, Volume. 14, Issue 5, 903(2006)

Stereo camera calibration based on accurate control points

CHEN Hua*... YE Dong, CHE Ren-sheng and CHEN Gang |Show fewer author(s)
Author Affiliations
  • [in Chinese]
  • show less
    References(11)

    [1] [1] ZHANG ZH Y.A flexible new technique for camera calibration[J].IEEE Transactions on Patten Analysis and Machine Intelligence,2000,22(11):1330-1334

    [2] [2] QIU M L,MA S D,LI Y.Overview of camera calibration for computer vision[J].Acta Automatica Sinica,2000,26(1):43-54

    [3] [3] WENG J,COHEN P,HERNIOU M.Camera calibration with distortion models and accuracy evaluation[J].IEEE Transactions on Pattern Analysis and Machine Intelligence,1992,14 (10):965-980

    [4] [4] SALCI J,ARMANGUE X,BATLLE J.A comparative review of camera calibrating methods with accuracy evaluation[J].Pattern Recognition,2002,35(7):1617-1365

    [5] [5] LENZ R K,TSAI R Y.Techniques for calibration of the scale factor and image center for high accuracy 3D machine vision metrology[J].IEEE Int.Conf.Robotics Automat,1987:68-75

    [6] [6] TSAI R Y.A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lens[J].IEEE J.Robotics Automat,1987,3 (4):323-344

    [7] [7] MAO J F,ZOU X Y,ZHU J.Improved two-stages camera calibration from a plane[J].Journal of Image and Graphics.July 2004,9(7):846-852

    [8] [8] HARTELY R,ZISSERMAN A.Multiple view geometry in computer vision[M].An Hui University Publication.2002:65-69

    [9] [9] HARTLEY R.In defence of the 8-point algorithm[J].Proceedings of the 5th International Conference on Computer Vision,IEEE Computer Society Press.Magn.Boston.1995:1064-1070

    [10] [10] MA S D,ZHANG ZH Y.The computer vision[M].Science Press,1997:97-98

    [11] [11] CHEN G,CHE R SH,YE D,et al.Stereo vision sensor field calibration method based on volume template[J].Optics and Precision Engineering.2004,12(6):626-631

    CLP Journals

    [1] LI Jian-rong, GAO Hui-bin, WANG Zhi-qian, SHEN Cheng-wu, LIU Shao-jin. Real-time compensative leveling in photoelectric measuring equipment[J]. Optics and Precision Engineering, 2010, 18(7): 1543

    [2] Yang Bowen, Zhang Liyan, Ye Nan, Feng Xinxing, Li Tielin. Camera Calibration Technique of Wide-Area Vision Measurement[J]. Acta Optica Sinica, 2012, 32(9): 915001

    [3] Zhao Min, Zheng Xingchun, Huang Qiuhong, Zhu Lingjian. Camera Calibration with Narrow Field of View for Deep Space[J]. Laser & Optoelectronics Progress, 2017, 54(9): 91502

    Tools

    Get Citation

    Copy Citation Text

    CHEN Hua, YE Dong, CHE Ren-sheng, CHEN Gang. Stereo camera calibration based on accurate control points[J]. Optics and Precision Engineering, 2006, 14(5): 903

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Nov. 16, 2005

    Accepted: --

    Published Online: Feb. 28, 2010

    The Author Email: Hua CHEN (aqua100@163.com)

    DOI:

    CSTR:32186.14.

    Topics