Journal of Atmospheric and Environmental Optics, Volume. 9, Issue 2, 138(2014)

High Accuracy Calibration Technology of Remote Sensor Tracing to Cryogenic Radiometer

Wei-wei PANG1、*, Xiao-bing ZHENG1, Jian-jun LI1, and Xue-shun SHI2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    References(19)

    [1] [1] Zheng Xiaobing, Wu Haoyu, Zhang Junping, et al. The NIST high accuracy cryogenic radiometer calibration and standard transmission method [J]. Chinese Science Bulletin, 2000, 45(12): 1341-1344(in Chinese).

    [2] [2] Goebel R, Stock M, Kohler R. Report on the international comparison of cryogenic radiometer based on transfer detector [R/OL]. BIPM Report 2000-9, http://www.bipm.org/pdf/Rapport- BIPM/ 2000/09.PDF.

    [3] [3] Fox N P. Primary radiometric quantities and units [J]. Metrologia, 2000, 37(5): 507-513.

    [4] [4] Li Zhaozhou. Studies of Highly Accurate Radiometric Calibration andApplication Based on Radiance Standard Detector [D]. Hefei: Doctorial Dissertation of Anhui Institute of Optics and Fine Mechanics, 2005(in Chinese).

    [5] [5] Wu Haoyu, Wang Guangyuan, Gou Yulong. Calibration study of trap radiation of Si photodiode [J]. Journal of Applied Optics, 1998, 19(2): 1-4(in Chinese).

    [7] [7] Varpula T, Seppa H, Saari J M. Optical power calibrator based on a stabilized green He-Ne laser and a cryogenic absolute radiometer [J]. IEEE Trans. Instrum. Meas., 1989, 38(2): 558-564.

    [8] [8] Foukal P, Lean J. An empirical model of total solar irradiance variation between 1874 and 1988 [J]. Science, 1990, 247(4942): 556-558.

    [9] [9] Zalewski E F, Duda C R. Silicon photodiode device with 100% external quantum efficiency [J]. Appl. Opt., 1983, 22(18): 2867-2873.

    [10] [10] Fox N P. Trap detectors and their properties [J]. Metrologia, 1991, 28(3): 197-202.

    [11] [11] Kohler R, Goebel R, Pello R. Result and international comparison of spectral responsivity of silicon photodetectors [J]. Metrologia, 1996, 32(6): 463-458.

    [12] [12] Touayar O, Reyn H, Bastie J, et al. Indirect comparison of cryogenic radiometers from the INM (France) and VTT (Finland) with a QED-200 from the VSL (Netherlands) [J]. Metroligia, 1995, 32(6): 561-564.

    [13] [13] Li Shuang. The Continuous Spectral Radiometric Calibration at a Wide Spectrum Based on Crvogenic Radiometer [D]. Hefei: Anhui Institute of Optics and Fine Mechanics, 2006 (in Chinese).

    [14] [14] Zou peng, Zheng Xiaobing, Wu Haoyu, et al. Research on calibration of radiance detector based on trap detector [J]. Acta Optica Sinica, 2013, 33(7): 41-46(in Chinese).

    [15] [15] Li Zhaozhou, Zheng Xiaobing, Tang Lingli, et al. An advanced technology of absolute radiometric calibration for optical remote sensors [J]. Journal of Remote Sensing, 2007, 11(4): 581-588(in Chinese).

    [16] [16] Johnson B C, Brown S W, Eppeldauer G P, et al. System-level calibration of a transfer radiometer used to validate EOS radiance scales [J]. Int. J. Remote Sens., 2003, 24(2): 339-356.

    [17] [17] Rice J P, Johnson B C. 1998. The NIST EOS thermal-infrared transfer radiometer [J]. Metroligia, 35(4): 505-509.

    [18] [18] Zou peng, Zheng Xiaobing, Wu Haoyu, et al. Development of multi-band radiance standard transfer detector [J]. Acta Optica Sinica, 2011, 31(4): 35-40(in Chinese).

    [19] [19] Zhou Lei, Peng Nina, Zhang Liming, et al. Detector based field radiometric calibration for the visible band of multi-channel scanning radiometer of satellite FY-2-05 [J]. Remote Sensing Technology and Application, 2007, 22(1): 20-25(in Chinese).

    Tools

    Get Citation

    Copy Citation Text

    PANG Wei-wei, ZHENG Xiao-bing, LI Jian-jun, SHI Xue-shun. High Accuracy Calibration Technology of Remote Sensor Tracing to Cryogenic Radiometer[J]. Journal of Atmospheric and Environmental Optics, 2014, 9(2): 138

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Oct. 30, 2013

    Accepted: --

    Published Online: Mar. 31, 2014

    The Author Email: Wei-wei PANG (earth35@163.com)

    DOI:10.3969/j.issn.1673-6141.2014.02.007

    Topics