Chinese Physics B, Volume. 29, Issue 9, (2020)

Dynamics and coherence resonance in a thermosensitive neuron driven by photocurrent

Ying Xu1,2, Minghua Liu1,3, Zhigang Zhu1, and Jun Ma1,4、†
Author Affiliations
  • 1Department of Physics, Lanzhou University of Technology, Lanzhou 730050, China
  • 2Department of Physics, Central China Normal University, Wuhan 430079, China
  • 3Electrical Engineering College, Northwest Minzu University, Lanzhou 70124, China
  • 4School of Science, Chongqing University of Posts and Telecommunications, Chongqing 30065, China
  • show less
    Figures & Tables(18)
    Schematic diagram for the neural circuit, which is dependent on the illumination and temperature. NR is a nonlinear resistor, C is the capacitor, L represents an induction coil, RT denote a thermistor, R and RS are linear resistors, and E is a constant voltage source. K denotes the cathode and A represents the anode in the phototube. The relation between the resistance of thermistor and temperature T is estimated with RT = R∞ exp(B/T), and the material parameter B is determined by the activation energy q and the Boltzmann’s constant K′ with the dependence as B = q/K′.
    Sampled time series for variable x and formation of attractors: (a), (e) A = 0.5; (b), (f) A = 0.66; (c), (g) A = 0.9; (d), (h) A = 1.3, and the parameters are fixed at T′ = 5, u0 = 0.2, ω = 1.004, b0 = 0.8, a = 0.7, c = 0.1, ξ = 0.175. b0 is the maximal resistance of the thermistor.
    Sampled time series for variable x and formation of attractors: (a), (e) A = 0.76; (b), (f) A = 0.83; (c), (g) A = 0.99; (d), (h) A = 1.36, and the parameters are fixed at T′ = 1, u0 = 0.2, ω = 1.004, b0 = 0.8, a = 0.7, c = 0.1, ξ = 0.175. b0 is the maximal resistance of the thermistor.
    Bifurcation diagram is calculated by detecting interspike intervals (ISIs) from the sampled time series for the variable x when the amplitude of voltage source is changed: (a) T′ = 0.5; (b) T′ = 1; (c) T′ = 5; (d) T′ = 20, and the parameters are fixed at u0 = 0.2, ω = 1.004, b0 = 0.8, a = 0.7, c = 0.1, ξ = 0.175.
    (a)–(c) Sampled time series for variable x, (d)–(f) formation of attractors, and (g) bifurcation diagram vs. angular frequency. For (a), (d) ω = 0.005; (b), (e) ω = 0.01; (c), (f) ω = 0.05, and the parameters are fixed at T′ = 10, A = 1, u0 = 0.2, b0 = 0.8, a = 0.7, c = 0.1, ξ = 0.175.
    Bifurcation diagram is calculated by detecting ISIs from the sampled time series for the variable x when the frequency of voltage source is changed: (a) T′ = 0.5; (b) T′ = 1; (c) T′ = 5; (d) T′ = 10, and the parameters are fixed at u0 = 0.2, A = 1, b0 = 0.8, a = 0.7, c = 0.1, ξ = 0.175.
    Bifurcation diagram is calculated by detecting ISIs from the sampled time series for the variable x when the amplitude of thermistor is changed: (a) T′ = 0.5; (b) T′ = 1; (c) T′ = 5; (d) T′ = 10, and the parameters are fixed at u0 = 0.2, A = 1, ω = 1.004, b0 = 0.8, a = 0.7, c = 0.1, ξ = 0.175.
    Bifurcation diagram is calculated by detecting ISIs from the sampled time series for the variable x when the temperature for thermistor is changed: (a) b0 = 0.6; (b) b0 = 0.7; (c) b0 = 0.8; (d) b0 = 0.9, and the parameters are fixed at u0 = 0.2, A = 1, ω = 1.004, a = 0.7, c = 0.1, ξ = 0.175.
    Correlation between temperature, resistance of thermistor, firing patterns and Hamilton energy are calculated by changing the temperature of the thermistor. For (a1)–(a4) b0 = 0.1; (b1)–(b4) b0 = 0.4; (c1)–(c4) b0 = 0.6, and the parameters are fixed at u0 = 0.2, A = 1, ω = 1.004, a = 0.7, c = 0.1, ξ = 0.175.
    Firing pattern and photocurrent are calculated as functions of time by applying different temperatures for the thermistor. For (a) T′ = 10; (b) T′ = 30, and the parameters are fixed at I0 = 0.05, b0 = 0.3, a = 0.7, c = 0.1, ξ = 0.175, va = 1 (black line), va = 0.1 (red line). The photocurrent is released from t = 200 time units.
    Mean duration of spiking is calculated by changing the parameters (I0, T′) with b0 = 0.3, T′ = 10 (red line-square), T′ = 20 (orange line-circle), T′ = 30 (violet line-up triangle). For (a) I0 = 0.1; (b) va = 0.1.
    Bifurcation diagram is calculated by detecting ISIs from the sampled time series for the variable x when the amplitude for photocurrent is changed. For (a) va = 1.0; (b) va = 0.1, and the parameters are fixed at b0 = 0.3, T′ = 10 (black dots), T′ = 30 (red dots), a = 0.7, c = 0.1, ξ = 0.175.
    Bifurcation diagram is calculated by detecting ISIs from the sampled time series for the variable x when the inverse threshold for photocurrent is changed. The parameters are fixed at b0 = 0.3, I0 = 0.2, T′ = 10 (black dots), T′ = 20 (red dots), T′ = 30 (blue dots), a = 0.7, c = 0.1, ξ = 0.175.
    Correlation between temperature, resistance of thermistor, firing patterns and Hamilton energy are calculated by changing the temperature for the thermistor. For (a1)–(a4) b0 = 0.1; (b1)–(b4) b0 = 0.3; (c1)–(c4) b0 = 0.5, and the parameters are fixed at I0 = 0.05, va = 1.0, a = 0.7, c = 0.1, ξ = 0.175.
    (b) Sampled time series for the variable x and (c) attractor are calculated when the temperature for the thermistor is adjusted as (a) T′ = 10.2 + 10 cos 0.1001τ. The parameters are selected as a = 0.7, c = 0.1, ξ = 0.175, IS = 0.0, b0 = 0.01.
    (c) Sampled time series for the variable x and (b) resistance of thermistor are calculated when the temperature for thermistor is adjusted as (a) T′ = 10.2 + 10 cos 0.01τ. The parameters are selected as a = 0.7, c = 0.1, ξ = 0.175, IS = 10 arctan(25x – 10), b0 = 0.01.
    Coefficient variability of ISI series is calculated by changing the noise intensity when the phototube is used as voltage source. The parameters are fixed at a = 0.7, c = 0.1, ξ = 0.175, u0 = 0.2, A = 0.76, ω = 1.004, b0 = 0.8, T’ = 1. During getting the average ISI, the threshold for peaks is selected as 0.3.
    Coefficient variability of ISI series is calculated by changing the noise intensity when the phototube is used as current source. The parameters are fixed at a = 0.7, c = 0.1, ξ = 0.175, I0 = 0.19, va = 1, b0 = 0.3, T’ = 10. During getting the average ISI, the threshold for peaks is selected as 0.3.
    Tools

    Get Citation

    Copy Citation Text

    Ying Xu, Minghua Liu, Zhigang Zhu, Jun Ma. Dynamics and coherence resonance in a thermosensitive neuron driven by photocurrent[J]. Chinese Physics B, 2020, 29(9):

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: May. 16, 2020

    Accepted: --

    Published Online: Apr. 29, 2021

    The Author Email: Ma Jun (hyperchaos@163.com)

    DOI:10.1088/1674-1056/ab9dee

    Topics