Infrared and Laser Engineering, Volume. 51, Issue 9, 20210921(2022)

Design of laser parameter measurement system based on diffuse reflection imaging

Yilun Cheng1,2,3, Fengfu Tan1,3, Feng He1,3, Zaihong Hou1,3, Laian Qin1,3, Hao Wang1,3, Zhigang Huang1,3, and Decheng Wu1,3
Author Affiliations
  • 1Key Laboratory of Atmospheric Optics, Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China
  • 2University of Science and Technology of China, Hefei 230026, China
  • 3Advanced Laser Technology Laboratory of Anhui Province, Hefei 230037, China
  • show less
    Figures & Tables(10)
    Measurement system structure diagram
    Schematic diagram of diffuse reflection target surface
    Spot image before and after distortion correction. (a) Spot image before distortion correction; (b) Spot image after distortion correction
    Schematic diagram of system tracking accuracy test
    Curve of spot centroid position under different powers
    Relationship between ADU and attenuation system transmittance
    • Table 1. Diffuse target surface hemispherical reflectance data

      View table
      View in Article

      Table 1. Diffuse target surface hemispherical reflectance data

      Wavelength/nmDirectional hemispherical reflectance
      10300.918
      10400.918
      10500.919
      10600.919
      10640.920
      10700.920
    • Table 2. Position coordinates of feature points after distortion correction

      View table
      View in Article

      Table 2. Position coordinates of feature points after distortion correction

      Actual coordinate in Y direction/pixel Actual coordinate inX direction/pixel Ideal coordinate in Y direction/pixel Ideal coordinate in X direction/pixel Y direction deviation/pixel X direction deviation/pixel
      132.92167.39132.54167.390.380
      133.28852.32135.93854.68−3.65−2.36
      818.89167.82820.93169.16−2.04−1.34
      817.74852.38820.93854.68−3.19−2.3
    • Table 3. Coordinate data of spot centroid position

      View table
      View in Article

      Table 3. Coordinate data of spot centroid position

      Laser output power/WFirst location coordinates (X-direction)/mm Second location coordinates (X-direction)/mm Deviation/mmThird location coordinates (X-direction)/mm Deviation/mm
      ≈3000−19.03−29.2410.21−39.2810.04
      ≈1500−18.93−29.0410.10−39.0510.01
      ≈1000−18.92−29.0110.09−39.0310.02
      ≈560−18.84−28.9010.06−38.899.99
    • Table 4. Results of laser power measurement

      View table
      View in Article

      Table 4. Results of laser power measurement

      Laser output power/W Attenuation system transmittance Measured laser power/W Uncertainty of measurement
      18701.66E-0518700
      13402.72E-0514004.29%
      12204.13411E-0511208.93%
      6209.26837E-055846.20%
    Tools

    Get Citation

    Copy Citation Text

    Yilun Cheng, Fengfu Tan, Feng He, Zaihong Hou, Laian Qin, Hao Wang, Zhigang Huang, Decheng Wu. Design of laser parameter measurement system based on diffuse reflection imaging[J]. Infrared and Laser Engineering, 2022, 51(9): 20210921

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Photoelectric measurement

    Received: Feb. 20, 2022

    Accepted: --

    Published Online: Jan. 6, 2023

    The Author Email:

    DOI:10.3788/IRLA20210921

    Topics