Noise equivalent radiance calibration system for infrared Fourier spectrometer at low-temperature and vacuum environment
[1] [1] ASMUS V V, TIMOFEYEV Y M, POLYAKOV A V, et al. Atmospheric temperature sounding with the fourier spectrometer[J]. Izvestiya Atmospheric & Oceanic Physics, 2017, 53(4): 428-432.
[2] [2] FRANK T G, NATASHA M J, JOSEPH A N. On the use of fourier transform infrared (FT-IR) spectroscopy and synthetic calibration spectra to quantify gas concentrations in a fischer-tropsch catalyst system[J]. Applied Spectroscopy, 2015,69(10): 1157-1169.
[3] [3] HONNIBALL C I, CASEY I R, WRIGHT,et al. MWIR hyperspectral imaging with the MIDAS instrument[J]. Proc. of SPIE,2017 ,10177: 101770J1-8.
[4] [4] WURST N P, JOSEPH M D, PERRY L. Measurement and modeling of longwave infrared directional downwelling spectral radiance[J]. Proc. of SPIE,2015 ,9611: 96110X1-8.
[5] [5] SILNY J F, ZELLINGER L. Radiometric sensitivity contrast metrics for spectral remote sensors[J]. Optical Engineering, 2017, 56(8): 081807.
[6] [6] MANNING C, GROSS M, SAMUELS A NESR. Characterization of a novel interferometer[J]. Fourier Transform Spectroscopy, 2003, 3(1): 114-116.
[8] [8] MEKHONSEV S, KHROMECHENKO V, PROKHOROV A. et al. Establishing a new NIST facility for the primary realization of both spectral radiance and reflectance in the mid-and far-infrared[C]//American Geophysical Union, Fall Meeting 2009, GC43A-0793.USA: [s.n.],2009.
[9] [9] MONTE C, GUTSCHWAGER B, MOROZOVA S P, et al. Radiation thermometry and emissivity measurements under vacuum at the PTB[J]. International Journal of Thermophysics, 2009, 30(1): 203-219.
[10] [10] MONTE C, GUTSCHWAGER B, ADIBEKYAN A, et al. Radiometric calibration of the in-flight blackbody calibration system of the GLORIA interferometer[J]. Atmospheric Measurement Techniques, 2014, 7: 13-27.
[11] [11] IVANOV V S, LISIANSKY B E, MOROZOVA S P, et al. Medium-background radiometric facility for calibration of sources or sensors[J]. Metrologia, 2000, 37(5): 599-602602.
[13] [13] RENTZ J H, EEGEL J R. Passive spectro-radiometer calibration: radiance responsivity, sensitivity, and radiation reference[J]. Fourier Transform Spectroscopy, 199913(1): 117-119.
[14] [14] LI Xunniu, ZHENG Weijian, LEI Zhenggang, et al. Analysis for signal-to-noise ratio of hyper-spectral imaging FTIR interferometer[J]. Proc. of SPIE, 2013, 8910: 89101P1-10.
[15] [15] ZHENG Weijian, JIN Weiqi, SU Junhong. NESR of long-distance passive infrared telemetering systems[J]. Infrared Technology, 2007, 29(9): 512-514.
[16] [16] YUAN Yinlin, ZHENG Xiaobing, WU Haoyu, et al. Uniformity research of integrating spheres reference light source with large exit aperture[J]. Acta Photonica Sinica, 2015, 44(4): 0422003.
[17] [17] ZHANG Mengya, YUAN Yinlin, ZHAI Wenchao, et al. Design and test of infrared integrating sphere radiation source with wide dynamic range[J]. Acta Optica Sinica, 2019, 39(6): 0612006.
Get Citation
Copy Citation Text
HANG Sijia, XIA Maopeng, LI Jianjun, ZHENG Xiaobing, LEI Zhenggang. Noise equivalent radiance calibration system for infrared Fourier spectrometer at low-temperature and vacuum environment[J]. Journal of Applied Optics, 2019, 40(6): 1103
Category:
Received: Jun. 25, 2019
Accepted: --
Published Online: Feb. 11, 2020
The Author Email: Sijia HANG (280678518@qq.com)