Optics and Precision Engineering, Volume. 24, Issue 11, 2783(2016)
Influence of bias magnetic field on detection voltage of magnetostrictive liquid level sensor
[1] [1] WANG B W, ZHANG L Y, WANG P, et al.. Analysis of detection signal for magnetostrictive displacement sensor [J]. Opt. Precision Eng., 2016, 14(2): 358-364.(in Chinese)
[3] [3] FEMANDO S, JOSE M M, ANTONIO R J. Improving the accuracy of magnetostrictive linear position sensors [J]. IEEE Transactions on Instrumentation and Measurement, 2009, 3(58): 722-728.
[4] [4] JIANG J SH, CHEN W M. Study on cable tension stress influence of cable tension sensor based on Villari-Effect [J]. Chinese Journal of Sensor and Actuators, 2009, 3(22): 439-441.(in Chinese)
[5] [5] XUE G M, ZHANG P L, HE ZH B, et al.. Modelling and experiment of strong bias giant magnetostrictive actuators semi-static displacement [J]. Transactions of the Chinese Society for Agricultural Machinery, 2015, 46(7): 318-324.(in Chinese)
[6] [6] MAO J, XIE CH X, MENG Y, et al.. Study on magnetostrictive liquid level sensor temperature compensation method [J]. Control Engineering of China, 2015, 22(5): 921-926.(in Chinese)
[7] [7] YANG X H, HUANG J, LU X CH, et al.. Design of intelligent magnetostrictive liquid level gauge [J]. Transducer and Microsystem Technologies, 2016, 35(3): 118-123.(in Chinese)
[8] [8] LIU X L, WU Y J, ZHANG Y ZH, et al.. Hybrid rate-dependent hysteresis model in giant magnetostrictive actuaor [J]. Transactions of the Chinese Society for Agricultural Machinery, 2014, 45(7): 286-291.(in Chinese)
[9] [9] ZHANG L Y, WANG B W, WENG L, et al.. The output voltage model of magnetostrictive displacement sensor in helical magnetic fields and its experimental study [J]. Transactions of China Electrotechnical Society, 2015, 30(12): 21-26.(in Chinese)
[10] [10] SUN Y, JIN H, ZHENG Y, et al.. Detective signal influence factor analysis and experimental research of magnetostrictive liquid level sensor [J]. Chinese Journal of Sensor and Actuators, 2015, 28(11): 1607-1613.(in Chinese)
[11] [11] YU CH, ZHOU X ZH. Research on excitation signal of Fe83Ga17 magnetostrictive displacement sensor based on ANSYS and DSP [J]. Instrument Technique and Sensor, 2012(8): 4-6.(in Chinese)
[12] [12] ZHU R, LV F Z, TANG ZH F, et al.. Bias bagnetic field optimization of longitudinal modes guided wave sensor based on magnetostriction [J]. Chinese Journal of Sensor and Actuators, 2011, 24(3): 371-375.(in Chinese)
[13] [13] ZHANG L, BU X ZH, ZHAO W. Optimal design of detecting coil and energizing pulse in magnetostrictive displacement sensor [J]. Process Automation Instrumentation, 2011, 32(5): 59-62.(in Chinese)
[14] [14] WANG ZH, CHANG X M, HIROYUKI W. Study on impulse wave of magnetostrictive position line sensor [J]. Journal of Taiyuan University of Technology, 2010, 41(3): 241-244.(in Chinese)
[15] [15] WANG ZH, CHANG X M, HIROYUKI W. Magnetic pole intensity model of magnetostrictive position sensor [J]. Chinese Journal of Sensor and Actuators, 2010, 23(8): 1075-1078.(in Chinese)
[16] [16] DAI Q G, ZHOU X ZH. Modeling and analysis of elastic wave of large-range magnetostrictive displacement sensor [J]. Chinese Journal of Sensor and Actuators, 2013, 26(2): 195-199.(in Chinese)
Get Citation
Copy Citation Text
SUN Ying, BIAN Tian-yuan, WANG Shuo, WENG Ling, ZHANG Lu-yu. Influence of bias magnetic field on detection voltage of magnetostrictive liquid level sensor[J]. Optics and Precision Engineering, 2016, 24(11): 2783
Category:
Received: May. 20, 2016
Accepted: --
Published Online: Dec. 26, 2016
The Author Email: Ying SUN (sunying@hebut.edu.cn)